Installation
(Continued)
PRIME
OUTLET
PLUG
PRESSURE
SWITCH
28-30 PSI PRECHARGE
1/2, 1/3 & 1 HP
Figure 7 - Pre-charged Storage Tank
3. Install a valve and isolator hose between
the system and the house plumbing to
aid in pump removal for servicing and
for reducing noise transmitted to the
house through the piping.
4. Provide a hose bib (faucet) at the
lowest point in the system to drain
for service or storage.
TO AIR VOLUME
CONTROL
Figure 8 - Shallow Well Jet
CONVERTING THE DEEP WELL PUMP TO
SHALLOW WELL OPERATION (FIGURE 8)
For shallow wells (25 feet or less), a
bolt-on shallow well jet is available
as an accessory for deep well pumps.
The jet attaches to the front of the
pump with the two bolts provided and
converts the deep well pump into a
shallow well pump. The shallow well
jet has a 1 in. NPT inlet and a 1/8 in.
NPT opening for an air volume control.
For optimum performance, an inline
check valve on the inlet side of the
shallow well jet is recommended.
Electrical
Risk of electrical
shock. This pump is
designed for indoor installation only.
Select the proper size wire and
fuse (Chart 2). Time delay fuses are
recommended over standard fuses
for motor circuit protection. All pump
motors have built-in automatic overload
protection that will prevent damage to
the motor due to overheating.
until unit is permanently grounded.
Connect ground wire to approved ground
TO
then connect terminal provided.
SUCTION
A metal underground water pipe or
well casing at least 10 feet long makes
TO JET
the best ground electrode. If plastic
pipe or insulated fittings are used, run
TO DRIVE
a wire directly to the metal well casing
or use a ground electrode furnished by
the power company.
There is only one proper ground
terminal on the unit. The terminal is
located under the pressure switch cover,
is painted green and is identified as
GRD. The ground connection must be
made at this terminal (Figure 9).
The ground conductor must not be
smaller than the circuit conductors
supplying the motor.
The voltage of power supply must match
the voltage of the pump. The unit has
dual voltage motors preset at the factory
to 115 volts. The motors can be converted
to 230 volts by turning the voltage
selector to the desired voltage (see Figure
10, on page 5). Disconnect power, use
needle nose pliers to pull the selector out
JET
approximately 1/4 in., rotate, and then
reinsert in correct position.
GROUND
SCREW
Figure 9 - Electrical Connections
CHART 2 - RECOMMENDED FUSE AND WIRING DATA - 60 HZ MOTORS
HP
Volt
115
1/2
230
115
3/4
230
115
1
230
Do NOT connect to
electric power supply
LINE
MOTOR
0
Dual
to
Element
50
Fuse
250V
15
14
10
14
15
14
10
14
20
14
10
14
5
CWS Series
230 V
Figure 10 - Voltage Selector
Disconnect power
and release ALL
pressure from the system before
attempting to install, service, relocate
or perform any maintenance.
Operation
PRIMING THE SHALLOW WELL PUMP
To prevent damage
to the pump, do NOT
start motor until pump has been filled
with water.
NOTE: When the deep well pump is used
with the bolt-on shallow well jet, be sure
the control valve slot (Figure 11, on page
6) is in the vertical (open) position at all
times.
1. Remove prime plug.
2. Fill pump and piping completely full
of water.
3. Replace the prime plug.
4. Open a faucet to vent the system.
5. Start the motor. Water will pump in a
few minutes. If pump fails to prime in
5 minutes, stop motor and refill pump
with water. Priming time is proportional
to the amount of air in inlet pipe. Do
not allow pump to get hot.
6. Let the system operate for several
minutes to flush all pipes.
Distance in Feet
From Meter to Motor
51
101
to
to
100
200
Wire Size
12
10
14
14
12
8
14
14
12
8
14
14
www.waynepumps.com
115 V
201
to
300
8
14
6
12
6
12