B. Dangers and warnings
For inside use only. The machine is de-
signed for use under dry conditions only
and must not be used or stored under wet
conditions.
The machine must be operated with a po-
wer cord conforming to national specifica-
tions only. The conversion to comply with
national regulations must be carried out by
an electrician.
Check that the information on the name
plate conforms to the local voltage.
The power plug must be easily accessible.
The device must only be connected to
receptacles connected to the protective
conductor system.
Check connector lines and hoses (such
as power cord) regularly for damage (e.g.
kinks, cracks, porosity) or signs of ageing.
Machines with damaged connector lines,
hoses or other faults must not be operated.
Disconnect the machine from the mains
supply before any electrical work.
Never operate machine without supervisi-
on.
NEVER operate machine without belt cover
installed!
Danger of injury by being caught in the
machine. Never work with loose long hair
or loose clothing.
Wear safety glasses when working with the
high-speed grinder!
Danger of hand injury by cutting an bur-
ning.
The rotating tools are sharp and the objects
can get hot.
Wear appropriate personal protective equip-
ment when working with materials that
could endanger health.
When working with the machine dust or
vapour that may endanger health may be
generated. Adjust the required extraction
system for the type of dust
Switch the machine off after work.
C. Approved persons
This product is specified for use by persons older
than 14 years.
The machine must be operated by trained persons
only.
Repairs to electrical equipment that are not descri-
bed in this owner's manual must be carried out by an
electrician.
D. Preparing for operation
Before operation for the first time compare
the information on the name plate with the
local mains voltage.
The machine must be connected only to re-
ceptacles that are connected to the protec-
tive conductor system.
E. Repair
Repairs must be conducted by authorized technicians
only.
Repairs to electrical equipment that is not described
in this owner's manual must be carried out by an
electrician.
F. Specifications
Mains voltage:
Power consumption:
motor fuse:
Light fuse:
Speed:
Cable length:
Spindle:
Diameter of connection points for external extraction:
Dimensions (WxHxD):
Weight:
Lighting:
G. Limitation of liability
CMP Industries LLC will not accept any liability for
damages and warranty claims under the following
conditions:
• The product is used for purposes other than
those specified in the owner's manual.
• The product is modified in any way – except for
the changes described in the owner's manual.
• The product is repaired by persons who are
not authorised technicians or parts are not
replaced with original CMP Industries spare
parts.
• The product is used in spite of obvious safety
defects or damage.
• The product is subject to mechanical impact or
is dropped.
- 5 -
230 V, 50/60 Hz, 1.5 A
180 W
2x 6,3 A (T)
800 mA (T)
20.000/24.000 1/min.
1 m
shaft size 2.38 mm
internal: 58 mm
external: 68 mm
275 x 280 x 310 mm
approx. 14.3 kg
2x 12 V high-intensity lights