English
TROUBLESHOOTING
Before any installation or maintenance operation, ensure that the power supply has been disconnected.
Use only original Gi.Bi.Di. spare parts and accessories.
Power LED of f
The card does not learn the TX code
Fast flashing of the programming LED (PROG.)
Cour tesy lamp not working
The operator does not open
The operator opens but does not reclose
The operator does not decelerate
Photocell entrance does not inter vene
PROFESSIONAL AUTOMATIC SYSTEM FOR GATES AND GARAGE DOORS
FAULT
12
POSSIBLE CAUSE / REMEDY
-
Check the fuses and the power cable (1 A)
-
Check the maximum number of storable codes
-
Check the frequency of the radio control and the receiver
-
Max. number of codes reached
-
Memor y fault
-
Check the lamp and the fuse F3
-
If the operator is batter y-powered
(230VAC power supply failure)
the cour tesy lamp is disabled.
-
Check the opening limit switch
Check the connection between card and limit switch
-
-
Check the inputs of the safety switches, photocells, Stop, etc.
-
Check the Star t input, it must be open
-
Check connection and opening limit switch
-
Check door balancing
Check limit switch inter vention
-
Verify that DIP 5 is in OFF
-