4. If burner goes out, wait 5 minutes and repeat lighting procedure.
5. When burner lights, open burner valve to ON position, to operate heater. Partially close valve to regulate
heat output.
Note: Adjusting burn rate too low can cause soot. Watch for and avoid a yellow flame.

RELIGHTING INSTRUCTIONS

1. Rotate valve on cylinder clockwise to close it, and wait five (5) minutes.
2. Relight following the LIGHTING INSTRUCTIONS.

SHUT-DOWN INSTRUCTIONS

1. Turn Control Knob to the OFF position
2. Rotate valve on cylinder clockwise to close it
WARNING: NEVER ATTEMPT TO SERVICE THIS HEATER WHILE
IT IS STILL OPERATING, OR HOT OR CONNECTED TO THE
GAS SUPPLY. SEVERE BURNS CAN RESULT.

VENTILATION

For these heaters, provide a minimum of 2.5 square feet of space for the MH-0080-CM10, or a minimum
of 6 square feet of space for the MH-0200-CM10 by opening a window or door to provide fresh, outside
air. Provide at least 3 square feet of opening for ventilation per 50,000 BTU of rated operation.
MAINTENANCE AND STORAGE
Inspect your heater before each use. Check all connections for leaks, following the procedure outlined in
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A FUEL
SOURCE.
Propane Convection Heater Manual
OPERATION
13