Operation
Twilight setting controller
The switch-on threshold of the motion detec-
tor can be adjusted infinitely variably from
approx. 2 to 1000 lx.
Night mode approx. 2 lx
Day mode
Switches regardless of brightness
level.
Set the setting controller to
The LED flashes five times for
confirmation.
Teach-in
Save ambient brightness as bright-
ness threshold.
Set the setting controller to
The LED flashes five times for
confirmation.
After 10 seconds, the measured
ambient brightness value is saved.
The load is switched off.
Change value: Set the setting con-
troller to any twilight value and then
reset it to
Setting controller time
Min.
delay time approx. 5 seconds
Max.
delay time approx. 15 minutes
Short-time operation, the output is
switched on for approx. 1 second.
Afterwards, no movement is evalu-
ated for approx. 8 seconds.
I
Note
If short-term operation
using the setting controller, the time
cannot be set using the remote con-
trol.
to calibrate a new value.
is set
Operation with connected switch
The switch should be operated in the range of
0.5 to 1 second.
Switch 1x
Switch 2x
Switching again cancels the permanent ON
operating state.
.
Mounting and electrical con-
nection
J
.
Selecting the installation location
- The installation location should have a dis-
tance of at least 50 cm from any other
light, since heat radiation can trigger the
motion detector.
- Select a installation location that is free of
vibrations, as vibrations can lead to unin-
tentional switching.
- Take the direction of walking into account.
- Optimum mounting height of 2.50 m.
- Not included in scope of supply. Wall
plugs, ø 6, and round head screws
6 x 35 mm for assembly.
Detection field
Motion detector Cube 120, mounting height
2.5 m (Fig. 18)
Motion detector Cube 240, mounting height
2.5 m (Fig. 19)
Light ON
Continuously
ON
DANGER!
Risk of death from electric shock.
Isolate the device. Cover any live
parts.
for set delay
time
for 2 hours
17