Kübler CODIX 521 Instrucciones De Puesta En Servicio página 12

Contadores indicadores electrónicos
Ocultar thumbs Ver también para CODIX 521:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the factor
settings
4.1 Polarity of the inputs
npn: switching for 0 V
pnp: switching for +U
4.2 Switching on the 30 Hz filter
The filter provides input damp-
ing*
30 Hz filter off (f
30 Hzfilter on
4.3 Multitplying factor
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0" is not accepted!
4.4 Dividing factor
It can be set from 00.0001 up
to 99.9999.
The decimal point is set to 4
decimal places.
„0" is not accepted!
4.5 Decimal point
The decimal point defines the
resolution in the selected
measuring range 1/min or
1/sec
0
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
4
B
)
max
no decimal place
4.6 Display mode
Value conversion and
display in 1/s
Value conversion and
display in 1/min
4.7 Max. time to wait until „0" is displayed
This parameter indicates, how long it takes,
when measuring is active, until „0" is displayed.
Max. time to wait 00.1 s
(min. value)
Max. time to wait 99.9 s
4.8 End of programming
The programming routine is
repeated once more. The val-
ues set until now can be
checked and modified.
The programming routine wil be
left and all values set will be
stored as new parameters.
Afterwards the device is ready
for operation.
Time meter CODIX 523
(CODIX 524: Operating mode time meter)
1. Description
• 6 digit time meter with SET/RESET function
• Red LED display, character height 8 mm
• Display range from 0 to 999 999
• Leading zeros suppression.
• Operation indicator: the decimal point of the
lowest digit blinks while the count is active.
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• Time meter operating modes
– Counting while INP B is inactive (GAtE.Lo)
– Counting while INP B is active (GatE.hi)
– Count Start/Stop with INP B edge (Inb.Inb)
– Count Start with INP A edge, count Stop with
* where bounce occurs, e.g. with contacts

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Codix 522Codix 523Codix 524

Tabla de contenido