only electrical reset via the
SET/RESET input
only manual reset via the red
SET/RESET key
4.8 SET value
The device will be set to the set
point by pressing the red
SET/RESET key or activating
the SET/RESET input.
SET value 0 ...999 999 or
99.59.59 (number of decimal
places depends on the decimal
point option)
4.8 End of programming
The programming routine is
repeated once more. The val-
ues set until now can be
checked and modified.
The programming routine wil be
left and all values set will be
stored as new parameters.
Afterwards the device is ready
for operation.
5. Technical data
Supply voltage
DC power supply:
Display:
Data retention:
Polarity of the inputs:
Input resistance:
6
10 ... 30 V DC/max. 55 mA
with inverse-polarity pro-
tection
6 digits, red 7 segment
LED display, height 8 mm
EEPROM
Programmable, npn or pnp
for all inputs
appr. 5 kOhm
Count frequency CODIX 521:
24 V
Power supply DC:
Input level:
Standard
typ. Low Level:
2,5 V
typ. High Level:
22,0 V
Fmax*:
kHz
CntDir
60
UpDown
25
Up.Up
25
Quad1
25
Quad2
25
Quad4
15
Count frequency CODIX 522:
Frequency measurement
Accuracy <0.1 %
Measuring principle:
< 38 Hz:
> 38 Hz:
Power supply DC:
Input level:
Standard 5V
typ. Low Level:
2,5 V
typ. High Level:
22,0 V
Fmax*:
Tacho
Counting ranges CODIX 523:
Seconds
Minutes
Hours
h.min.s
Accuracy
Minimum pulse length for the Reset input:
Input sensitivity:
Standard sensitivity:
4 ... 30 V DC level: Low: 0 ... 2 V DC
Pulse shape:
Optocoupler output (optional):
NPN optocoupler with open collector and open
emitter; max. switching performance:
30 V DC/10 mA
Ambient temperature:
-20 ... +65 °C at
10 ... 26 V DC
-20 ... +55 °C at >26 ... 30 V DC
Storage temperature:
Altitude:
EMC:
Noise emission
Noise immunity
12 V
10 ...30 V
2,0 V
1,0 V
10 V
4,0 V
kHz
20
15
15
15
15
15
period measurement
gating time measurement
gating time 26,3 ms
24 V
12 V
10 ...30 V
2,0 V
1,0 V
10 V
4,0 V
kHz
kHz
kHz
6
20
0.001 s ... 999999 s
0.001min ... 999999 min
0.001 h ... 999999 h
00 h 00 min 01 s
... 99 h 59 min 59 s
<50 ppm
5 ms
Low: 0 ... 0,2 x UB [V DC]
High: 0,6 x UB ... 30 V DC
High: 4 ... 30 V DC
any*, Schmitt-Trigger inputs
–25 ... +70 °C
to 2000 m
EN 55 011 Class B
EN 61 000-6-2
5V
kHz
8
8
8
8
8
8
8