TROUBLESHOOTING GUIDE

Trouble
Unit does not operate on any
speed setting
Motor does not turn on.
Display shows "00"
Not enough humidity.
Too much humidity.
(condensation becomes heavy on
cold surfaces in room)
Water leak
Odor
Control panel does not respond to
input. Display shows CL
Display flashes "20"
Display flashes "—"
Probable Cause
• No power to unit.
• Unit has run out of water and
turned off automatically.
• Refill switch operation/improper
positioning of float assy.
• Check motor/fan operation.
• Wick may be incorrectly installed.
• Unit just turned on.
• Wick is old and ineffective.
• Humidistat is not set high
enough
• Humidistat is set too high.
• Cabinet may have been overfilled.
There is a safety overflow hole in
rear of cabinet.
• Bacteria may be present.
• Control lock feature has been
turned on to prevent changes in
settings.
• ROOM Humidity is lower than 20%. • Will read actual humidity when
• Room humidity is over 90%.
9
Remedy
• Ensure polarized plug is fully
inserted in wall outlet.
• Refill reservoir.
• Ensure float assembly is correctly
positioned as described in
"Water FIll
• CAUTION: Do not touch the fan
when accomplishing this test,
as the motor may turn on.
• To test the motor, turn unit ON
and turn all knobs fully ON.
• Turn the chassis over and insert
finger into tab where float rod is
supposed to go. If fan turns on,
the fan and motor are working
correctly.
• Remove and reinstall wick
correctly.
• Unit is initiating.
• Fan speed is in standby
• Replace wick when clogged or
hardened with minerals.
• Increase humidity setting on
control panel.
• Reduce humidistat setting or
increase room temperature.
• DO NOT OVERFILL cabinet.
Correct water level is indicated
inside of cabinet side wall.
• Clean and disinfect cabinet
following Care and Maintenance
instructions.
• Add EPA registered Bacteria
Treatment according to instructions
on the bottle.
• It may be necessary to replace the
wick if odor persists.
• Press Humidity and Speed
buttons at same time for 5
seconds to deactivate feature.
level comes up to 25%.
• Will remain until humidity drops
below 90%.