Stand Alone Operation; Master Mode; Changing The Operating Mode - SSS Siedle FPM 611-02 Informacion De Producto

Módulo de huellas dactilares
Ocultar thumbs Ver también para FPM 611-02:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 32

Stand alone operation

Master mode

Scan in master fingerprint
The fingerprint module is in the
master mode in its as-delivered
status.
Conditions:
• Device is initialized
• Red LED is alight (as­delivered
status)
• Draw the master fingerprint over
the sensor. The green LED flashes for
appr. 3 secs, after which the red LED
lights up.
• Draw the master fingerprint over
the sensor again. The green LED
flashes appr. 3 secs, then the red
LED lights up.
• Draw the master fingerprint over
the sensor a third time. The green
LED flashes for appr. 3 secs, after
which the green LED lights up con-
tinuously. The master fingerprint has
now been scanned in and is valid.
It is now possible to scan in user
fingerprints.
If a finger has been drawn over
the sensor and not recognized,
the red LED flashes for 3 seconds,
after which the green LED lights up.
Repeat the scanning-in process.
Scan in user fingerprint
Conditions:
• Green LED is alight
(operating mode)
• Draw the master fingerprint once
over the sensor. The green LED
flashes for appr. 3 secs, then the red
LED lights up.
• Draw the user fingerprint over
the sensor. The green LED flashes
for appr. 3 secs, then the red LED
lights up.
• Draw the user fingerprint over the
sensor again. The green LED flashes
for appr. 3 secs, then the red LED
lights up.
• Draw the user fingerprint a third
time over the sensor. The green LED
flashes for appr. 3 secs, then stays
alight.
8
If a finger has been drawn over
the sensor and not recognized,
the red LED flashes for 3 seconds,
after which the green LED lights up.
Repeat the scanning-in process.
Check:
• Draw the user fingerprint once
over the sensor. The green LED
flashes and the relay picks up.
Changing the operating
mode
In order to operate the FPM 611-...
in accordance with special require-
ments, before commissioning you
must have set the relevant operating
mode. The operating mode is set
from the back of the module:
7 Module removal
Use the Vario key to unlock the
module. (See also Siedle Vario
product information)
8 Setting the operating mode
• Open the flap on the back of the
module with the aid of a screw-
driver.
• Set the required operating mode
(0 to 9) at the rotary switch. Once
the required operating mode has
been set, close the flap and replace
the module.
Possible operating modes:
1 = Master mode
5 = Group administrator mode
9 = Administrator mode
0, 2..4 and 6..8 = Delete mode
Group administrator
mode
Scan in group administrator
fingerprint
Conditions:
• Device is initialized
• Group administrator mode is set
(5), the red LED is alight (as-delivered
status)
The fingerprint you read in first in
the group administrator mode is the
group administrator fingerprint.
• Draw the group administrator fin-
gerprint over the sensor. The green
LED flashes for appr. 3 secs, after
which the red LED lights up.
• Draw the group adminstrator fin-
gerprint over the sensor again. The
green LED flashes for appr. 3 secs,
after which the red LED lights up.
• Draw the group administrator
fingerprint over the sensor for a
third time.
The green LED flashes for appr. 3
secs., then stays alight. The group
administrator fingerprint has now
been scanned in and is valid. It
is now possible to scan in group
master fingerprints.
If a finger has been drawn over
the sensor and not recognized,
the red LED flashes for 3 seconds,
after which the green LED lights up.
Repeat the scanning-in process.
Scan in the group master
fingerprint
• Draw the group administrator
fingerprint once over the sensor. The
green LED flashes for appr. 3 secs.
then the red LED lights up (scan-
ning mode for the group master
fingerprint).
• Draw the group master fingerprint
over the sensor. The green LED
flashes for appr. 3 seconds, then the
red LED lights up.
• Draw the group master fingerprint
over the sensor again. The green
LED flashes for appr. 3 secs., after
which the red LED lights up.

Publicidad

Tabla de contenido
loading

Tabla de contenido