Auto Test
Used to activate the internal "self-test" program which checks all possibilities of the unit.
 Press the MENU button until the display shows "Auto Test".
 Press the ENTER button to start the internal self-test program.
 To go back to the functions press the MENU button.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Temperature inside the unit
Used to show the temperature inside the unit
 Press the MENU button until the display shows "Temp.".
 Press the ENTER button to show the internal temperature of the unit on the display.
 To go back to the functions press the MENU button again.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Fixture Hours
Used to show the number of working hours of the unit.
 Press the MENU button until the display shows "Fixture Time".
 Press the ENTER button to show the number of working hours in the display.
 To go back to the functions press the MENU button.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Firmware version
Used to show the software version that is installed in the unit
 Press the MENU button until the display shows "Firmware Version".
 Press the ENTER button to show the software version on the display.
 To go back to the functions press the MENU button.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Reset
Used to force a reset of the unit.
 Press the MENU button until the display shows "Reset".
 Press the ENTER button to reset the unit.
If you want to go back to normal running mode: press the MENU button for about 2 seconds.
Please also check the chapter about the DMX-channel configuration of the unit to find out how you can force
a reset by DMX.
ELECTRICAL INSTALLATION + ADDRESSING
Important: The electrical installation should be carried out by qualified personal only,
according to the regulations for electrical and mechanical safety in your country.
Electrical installation for 1 standalone unit:
 Just insert the mains cable. The unit starts working immediately in stand-alone mode.
Remark1: You can connect a CA-8 or RF-8 remote controller to the unit if you want to have more control.
Refer to "how to operate the unit" to learn how to do this.
Remark2: if there's no output, please make sure to set the unit in master mode and set the blackout mode
to "M/S" and Sound State to "On" (see previous chapter)
Electrical installation for two or more units in master/slave:
In this mode the units will show a synchronized show, working to the rhythm of the beat.
 Connect 2 to maximum 16 units together using good quality balanced microphone cables. The first unit
in the chain will automatically act as the master, the other units will act automatically as slaves.
 Make sure that all units are connected to the mains.