Symbols and Terms
C - - A Toaster is set on Celsius.
F - - A Toaster is set on Fahrenheit.
A L -
Alarm Level setting 1 – 4.
Sound Button: Used with timer button and
temperature button to set alarm level.
Timer Button: Used to view time in run mode.
Used to set time in program mode.
Temperature Button: Used to view set point
temperature in run mode, and used to set the
set point temperature in program mode.
Up Arrow: Used to set time, sound and
temperature in program mode.
Down Arrow: Used to set time, sound and
temperature in program mode.
Energy Saving Mode
To conserve energy during non-toasting periods, pull
the toaster handle down, so that the timing cycle
activates. When the audio alarm goes off, indicating
that the toasting time is complete, DO NOT pull the
handle up. Allow the audio alarm to sound until the
alarm shuts off, the display will alternately flash
"Stand" and "By", indicating the toaster is in the
energy saving mode. The toaster platens will continue
to maintain the programmed operating temperature.
Raising the toaster handle will put the toaster back into
the operation mode.
Factory Pre-Set
Prince Castle's Solid State Digital Display toasters are
pre-set at the factory.
Model 411-SDFM85CE is set for a 35 second toast
time and the temperature is pre-set and calibrated to
215°C.
Model 411-SDFM11CE is set for a 100 second toast
time and the temperature is pre-set and calibrated to
249°C.
Printed in USA 4/06 © 2006
Equipment Set-Up
1. Refer to the nameplate on the control box for the
proper operating voltage. Connect the toaster to a
grounded receptacle that matches the nameplate
voltage information. Press the power switch to the
on position, allow the unit 30 minutes to reach
operating temperature.
2. The toaster is factory-set to display temperature
readings in Celsius. When the toaster is turned
on, the digital display on the control box will read
C - - A for Celsius, and the "A" will begin to count
down 9 seconds. During this countdown, you can
change the temperature display from Celsius to
Fahrenheit readings. To change the temperature
display, press and hold the temperature button for
six seconds. See figure 1.
figure 1
3. During the pre-heat cycle, the display will read
L O -. When the platen temperature reaches
149°C (300°F), the display will begin to show the
actual platen temperature throughout the toasting
cycles. See figure 2.
figure 2
6
411-561revB