User Instructions; Setting Parameters - Gewiss Chorus GW 10 763 Manual De Usuario

Termostato easy - de pared
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

The activation of the heating or air-conditioning operations are indicated as followed:
To set the thermostat parameters, press the SET key.
The word SET appears on the display and the symbol of the set operation type (heating
or air-conditioning) starts to flash.

USER INSTRUCTIONS

Heating
The
symbol indicates that the activation command has
been sent to the actuator which controls the boiler or the
zone electro-valve. If the thermostat does not receive
confirmation from the actuator that the same has been
activated, the
Subsequently, the thermostat sends the activation
command again, at one minute intervals, until it receives a
positive response.
Air conditioning
The
symbol indicates that the activation command
has been sent to the actuator which controls the air-
conditioner or the zone electrovalve. If the thermostat
does not receive confirmation from the actuator that the
same has been activated, the
Subsequently, the thermostat sends the activation
command again, at one minute intervals, until it receives
a positive response.
Operation with fan-coil control activated
The symbol
control is activated in the parameter settings.
Press the FAN key repeatedly to adjust the fan-coil speed
or set the AUTO mode option, where the fan-coil speed is
automatically regulated according to the difference
between the set-point set on the device and the current
temperature. The fan coil speed indicator flashes when
the fan is running.

Setting parameters

40
symbol starts to flash.
symbol starts to flash.
appears on the display if the fan-coil

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Chorus gw 14 763