VM TensioFlash KD-795 Manual página 73

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 26
Table 4
For ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING
Recommended separation distances between
portable and mobile RF communications equipment and the KD-795
The KD-795 is intended for use in an electromagnetic environment in which radiated RF
disturbances are controlled. The customer or the user of the KD-795 can help prevent elec-
tromagnetic interference by maintaining a minimum distance between portable and mo-
bile RF communications equipment (transmitters) and the KD-795 as recommended below,
according to the maximum output power of the communications equipment.
Rated maximum
Separation distance according to
output
frequency of transmitter m
of transmitter W
150 kHz
to 80 MHz
P √
d = 1.2
0.01
0.12
0.1
0.38
1
1.2
10
3.8
100
12
For transmitters rated at a maximum output power not listed above, the recommended separation
distance d in meters (m) can be determined using the equation applicable to the frequency of the
transmitter, where P is the maximum output power rating of the transmitter in watts (W) accor-
ding to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
144
Visiomed - KD-795 - 032016
80 MHz
800 MHz
to 800 MHz
to 2,5 GHz
P √
P √
d = 1.2
d = 2.3
0.12
0.23
0.38
0.73
1.2
2.3
3.8
7.3
12
23
Visiomed - KD-795 - 032016
Visiomed - KD-795 - 072014
145

Publicidad

Tabla de contenido
loading

Tabla de contenido