1. Work Mode
1.1 Setpoint Value Display (after switching on the device)
Main switch (3) ON
• After switching on the device, the values last set appear on the display (5) (Fig. 3).
• The heating, blower and drive are switched off in this menu.
• Here the user can perform all settings described in the following sections using the
controls (4).
• If, however, the heating element temperature is greater than 80°C when switching
on, the display will immediately change to the Cool Down mode (Section 1.8 Cooling)
in which the blower is always operated at full power, thus cooling down the
welding nozzle (9). You can change back to the Work Mode from this mode at any
time by pressing the e-Drive
• If the heating element temperature reaches 60°C during cooling, the blower will
continue to operate for 2 minutes and then switch off automatically. The display (5)
changes back to the Setpoint Value display (Fig. 3).
• Turning the e-Drive
(Fig. 4; Section 1.7 Selecting Profiles).
1.2 Work display
• Pressing the e-Drive
point Value display changes to the Work display.
• When the welding nozzle (9) is heating up, this is indicated on
the display (5) with a progress bar, arrow
value of the welding temperature (flashing) (Fig. 5).
Once the setpoint value of the welding temperature is reached,
the arrow and progress bar will no longer be displayed (Fig. 6).
• If the mains voltage is outside (+/- 15%) the specified nominal
voltage, the symbol will be displayed alternately with the measured
undervoltage
volume is 100 %, the symbol will be displayed flashing with the
measured undervoltage
(Only possible with VARIANT T1 230 V~).
Undervoltage/Overvoltage can affect the welding results!
• If no button is pressed after a definite time (welding nozzle (9)
NOT in welding position), the Standby menu will be displayed
(Section 1.9 Standby).
• If the welding nozzle (9) is in the parked position, the menus Cool Down (Section 1.8 Cooling) or Profiles
(Section 1.7 Selecting Profiles) can be selected by turning the e-Drive
• If the welding nozzle (9) is swivelled in, the two menu items
and can no longer be selected.
• While the welding nozzle (9) is cooling down, this is indicated with a filled out progress bar,
(down) and flashing actual value of the welding temperature on the display (5) (Fig. 8).
arrow
28
ON
.
to Profiles allows various welding profiles to be selected
starts the heating and blower and the Set-
/overvoltage
and the set air volume. If the air
/overvoltage
6.0
(up) and the actual
80
6.0
(Fig. 7).
6.0
620
Profile
6.0
620
80
6.0
620
80
6.0
520
520
80
%
Profile
(Fig. 5)
6.0
620
620
Profile
(Fig. 7)
.
will disappear on the display (5)
%
Profile
(Fig. 3)
%
Profile
(Fig. 4)
%
Profile
(Fig. 6)
Profile
(Fig. 8)