1. Work Mode

1.9 Standby

• If the welding nozzle (9) is not in the welding position and no but-
ton is pressed during a standby time defined by the user, Cool Down
mode will automatically start after the countdown has passed (Fig. 20).
The cooling down process is initiated.
• If the e-Drive
display (5) will change to Work Display (see Section 1.2 Work Display).
• Setting the standby time (Section 2.3 Standby Setup).

1.10 Error messages

• If a malfunction occurs in the hot-air welding
machine VARIANT T1, a message accompa-
nied by an error code will appear on the display
(5). This code stands for a more precise defini-
tion of the error which can be seen in the list
below.
• Separate symbols are displayed for error 02
and error 40.
• In case of all other errors, the spanner is displayed for the service prompt.
Error
Err00
Err01
Err02
Err04
Err08
Err40
2. Profile Setup

2.1 Profile Setup Button Combination

Keep Drive and Heating
buttons pressed
with main switch ON at
the same time.
32
is pressed before the countdown has passed (180 seconds), the
Type of error
Control electronics defective
Interruption or short-circuit of the temperature probe
Heating element / Electronics defective (interruption in one/both winding(s))
Triac defective (one or both Triacs are defective)
Blower motor defective
Undervoltage 25% (mains voltage 75%) only VARIANT T1 230 V~
ON
Release
1
2
3
(Fig. 20)