IFU_KR_EA84_NAFTA_EA84 25/10/13 11:01 Page19
If the message "Empty the two trays" is displayed, empty and clean the drip tray.
1. Remove, empty and clean the coffee grounds collector. Fig. 21.
2. Remove the coffee drawer.
Wait for at least 8 seconds, then first put the coffee drawer back in place and then the coffee
grounds collector tray. Fig. 22.
The drip tray is equipped with a float indicating when it requires emptying. Fig. 23.
Circuit rinsing
You can perform a rinsing cycle at any time by pressing Prog then maintenance. Depending
on the types of recipes prepared, the appliance will perform an automatic rinsing when
switching off.
Automatic cleaning programs
Automatic cleaning programs for the coffee circuit
The appliance will tell you when a cleaning program is required. One cleaning will be
required every 360 preparations (approximately).
To perform a cleaning cycle, you will need a container with a capacity of at least 20.3 oz;
this should be placed under the coffee outlets and you will need a KRUPS cleaning tablet.
Follow the instructions on-screen. It is also possible to launch cleaning via the maintenance
menu.
Important: you do not have to perform a cleaning cycle immediately when the appliance
!
requests this; however, you should do this as soon as possible. If cleaning is
delayed, an alert message
performed.
The automatic cleaning cycle includes two phases: a cleaning and a rinsing cycle; the
program takes about 13 minutes.
Important: if you disconnect your appliance during cleaning or in the event of a power
!
cut, the cleaning cycle will resume the stage in progress during the incident.
It will not be possible to delay this operation. It is mandatory to rinse the water
circuit. In this case, a new cleaning tablet may be required. Make sure the
entire cleaning cycle is completed to remove any traces of descaling product
that may be hazardous to your health.
Do not place your hands under the coffee outlets during the cycle.
Automatic descaling program for the steam circuit
Caution: if you installed a Claris - Aqua Filter System cartridge in the water tank,
!
please remove it before starting the descaling cycle.
The appliance will tell you when a descaling cycle is required. The frequency at which this
program needs to be run depends on the quality of the water used and whether the Claris
Aqua Filter System filter is used or not (the more limescale in the water, the more descaling
is required).
Important: you do not have to perform a descaling program immediately when the
!
appliance requests it; however, you should do this as soon as possible. If
descaling is delayed, an alert message
operation is performed.
will remain on the screen until the operation is
will remain on the screen until the
19