Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 36
GB
User Manual
• Do not freeze or immerse power supply in water
or any other liquid.
WARNING: Shock hazard. Don't allow any liquid
to get inside power supply. Electric shock may
result.
CAUTION: Never attempt to open the power
supply or any reason. The product has no user
serviceable parts inside.
Set Up
Laser Tool
• Place laser tool on a flat, stable surface.
• To power ON and activate the auto leveling
feature move the pendulum / transport lock to
the unlocked position. (Fig B #3)
• The laser tool must then be positioned in its
upright position on a surface that is within the
specified compensation range.
• Select the desired beam configuration by
pressing the beam activation key (Figure C #8)
repeatedly and cycling through the options
shown in Figure D.
Mounting on Accessories
• Position accessory in a place where it will not be
easily disturbed and near the central location of
the area to be measured.
• Set up the accessory as required. Adjust
positioning to be sure accessory base is near
horizontal (within laser tools compensation
range).
• Mount the laser tool to the accessory using the
appropriate fastening method to be used with
such accessory / laser tool combination.
CAUTION:
• Do not leave the laser tool unattended
on an accessory without fully tightening
the fastening screw. Failing to do so may
lead to the laser tool falling and sustaining
possible damage.
8
NOTE:
• It is best practice to always support laser
tool with one hand when placing or
removing laser tool from an accessory.
• If positioning over a target, partially tighten
the fastener, align laser tool, and then
fully tighten.

Operation

NOTE:
• Before operating the laser tool always be sure to
check the laser tool for accuracy.
• Laser tool will indicate when it is out of
compensation range. Reference LED Descriptions.
Reposition laser tool to be closer to level.
• When not in use, please be sure to power OFF
the laser tool by placing the pendulum lock in the
locked position.
Power
• To turn the laser ON move the pendulum /
transport lock to the unlocked position.(Fig B #3)
• To turn the laser OFF, move the pendulum /
transport lock to the locked position.
• Select the desired beam configuration by
pressing the beam activation key (Figure C #8)
repeatedly and cycling through the options
shown in Figure D.
Modes
OFF/ Locked (See figures
The laser will be OFF and the pendulum
locked.
ON/ Self-Leveling (See figures
The pendulum lock on the laser tool will be
positioned in the unlocked /self-leveling position
when the laser is turned ON.
The lasers are designed to self-level. If the
laser has been tilted > 4° then it cannot
self-level and the laser beam will flash. When
the beams flash THE LASER IS NOT LEVEL
(OR PLUMB) AND SHOULD NOT BE USED
FOR DETERMINING OR MARKING LEVEL OR
PLUMB. Try repositioning the laser on a more
level surface.
)
B
)
B

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fatmax fmht77357

Tabla de contenido