TEST AND ADJUSTMENT
1. Turn on the circuit breaker and light switch.
NOTE: Sensor has a 1
before it will detect motion. When first turned
on, wait 1
/
minutes.
1
2
2. Turn the RANGE control to the minimum position
(MIN), D
B
to OFF, and the ON-TIME control
®
ual
rite
to the TEST position.
MAX
ON - TIME
MIN
TEST 1 5 2 0
RANGE
MINUTES
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
8 ft.
(2.4 m)
70 ft.
(21 m) (30.5 m)
Maximum Range
NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is most sensitive to motion across its field
of view.
Motion
Sensor
Least Sensitive
/
minute warm up period
1
2
DUAL BRITE
OFF 3 6 DUSK TO
HOUR DAWN
240°
100 ft.
Boosted
Maximum
Coverage Angle
Motion
Most Sensitive
3. Loosen the clamp screw in the
sensor ball joint and gently
rotate the sensor.
4. Walk through the coverage
area noting where you are
when the lights turn on (also,
the LED will flash several
times when motion is detect-
ed). Move the sensor head up,
down, or sideways to change
the coverage area. Keep the
sensor at least 1" (25 mm)
away from the lamps.
5. AdjusttheRANGEasneeded.
RANGE set too high may
increase false triggering.
6. Secure the sensor head
by tightening the clamp
screw. Do not overtighten
the screw.
7. Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 20 minutes).
8. Set the D
B
ual
rite
after dusk you want the lights on at low level (Off,
3, 6 Hrs., Dusk-to-Dawn).
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.
Sensing Angle . . . . . . . Up to 240°
Electrical Load. . . . . . . Up to 500 Watt Maximum
Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL
Time Delay . . . . . . . . . 1, 5, 20 minutes
Replacement lamp. . . . T3, 500W (or less) halogen
D
B
Timer . . . . . 3, 6 hours, Dusk-to-Dawn
®
ual
rite
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.
4
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage
switch to the amount of time
®
(30.5 m) with Range Boost.
[varies with surrounding
temperature]
Incandescent
MODE
120 VAC
206442-01
Clamp
Screw
Ball
Joint