Introduction
• Before installing the system, read the instruction
herein.
• It is mandatory not to use the BOB 524 / BOB 524E
item for applications different from those indicated
in the instructions herein.
• Supply the end user with instructions for using this
system.
• The end user should receive special instruction manual.
• All Benincà items are covered by an insurance policy
for damages and injuries caused by manufacture
faults. It is however required that the machine
bear the CE marking and original Benincà parts be
used.
General information
To ensure a good operation of these automatic devices,
the gate to be automated should meet the following
requirements:
- good strength and stiffness.
- hinges should have a minimum backlash and allow
for smooth and regular manual operations.
- when closed, the gate leaves should correctly
overlap for their entire height.
How to install the automatic system
Calculate the height of the system from the ground
(it is advisable to define a position as much centred
as possible with respect to the main door and in
correspondence with a strong cross girder). Weld the
plate P, following measures in Fig. 1.
With the door closed, weld bracket S to a cross beam
of the main door or other element with equal strength,
according to measures shown in Fig. 1. Keep in mind
that, when carrying out this operation, the actuator
should not be totally in a stroke end position.
Remove the cover C by loosening the screw F. Then
fix the actuator to the plate P by means of the screw
T and the nut D (Fig. 2). Lock the actuator to plate S
by means of screw V and washer R.
The holes in the acturator (Fig. 1a-1b) help to keep to
the optimum installation measures.
How to adjust the mechanical stoppers
The actuator is provided with adjustable mechanical
stoppers in the opening and closing phases. The system
is adjusted by suitably positioning the "Open" and
"Close" mechanical locks, as shown hereunder (Fig.3):
1) Unlock the automatic system by using the special
release lever, as shown in the instructions for the
user (page 21-22).
2) Close the door/gate leaf.
3) Loosen screws V1 and move the "Close" lock until
it reaches the pivot P, then tighten screws V1.
4) Open the door/gate leaf.
5) Loosen screws V2 and move the "Open" lock until
it reaches the pivot P, then tighten screws V2.
6) Reset the automatic operating mode.
In the BOB 524 version, two limit micro-switches are
provided fixed to the mechanical stoppers.
The micro-switches trigger slightly in advance with
respect to the mechanical stop.
12
Connections
1) The special plate P (Fig. 4) allows for using a link for
sheath or cable gland PG11, or PG13,5. Once the
type of cable gland is applied to the plate, fix the
latter to the adaptor cover by means of screws V.
2) BOB 524: carry out the wiring by referring to the
wire diagram shown in Fig 5a.
3) BOB 524E: carry out the wiring by referring to wire
diagram shown in Fig 5b.
4) It is mandatory to provide for ground by using the
special GND terminal.
WARNING
The insurance policy, which covers any damages or
injuries caused by manufacture faults, requires that
the installation comply with regulations in force and
Benincà original accessories be used.
TECHNICAL DATA
Power supply
Absorbed rating
Absorbed current
Thrust
Jogging
Protection degree
Operating temperature
Door leaf max. weight
Useful stroke:
- with 2 mechanical stoppers
- with 1 mechanical stopper
- without mechanical stoppers
Translation speed
Noise level
Lubrication
Weight
BOB5024
BOB5024E
24Vdc
120 W
6 A
2000 N
intensive
IP54
-20°C / +70°C
500 kg
455 mm
485 mm
520 mm
0,8 m/min
<70 dB
Permanent
grease
11,6 kg