STEP 6: FINE-TUNE TANK WATER LEVEL
A: FLUSH THE TOILET
TO CHECK THE TANK
WATER LEVEL
After the water stops filling the
tank, the water level should be
roughly ½ inch below the top
of overflow pipe to ensure a
proper flush.
B: WATER LEVEL IS TOO LOW
Turn the tank water level adjustment screw
clockwise to raise the float. Flush to reset
water level.
WATER LEVEL IS TOO HIGH
Turn the water level adjustment screw
counterclockwise to lower the float. Flush
to reset water level.
+
Tank Water Level
Adjustment Screw
8
1/2"
Overflow
Pipe
See Step 5C for Full Tank view
STEP 7: FLUSH THE TOILET
A: FLUSH THE TOILET
If you're satisfied with the flush, YOU'RE DONE!
YOU DID IT!
We knew you could!
Share your success story
with friends and family!
#FixedMyToilet
#Fluidmaster
Still not working exactly right?
See the next page for Troubleshooting.
9