See Figure 14. Loosen motor mounting
bolts and slide motor along motor plate
to change belt span length. Belt
deflection should be measured as close
to the center of the span length as
possible. A set force should be applied
in the center of the span length, as
specified in the table below.
Machine
Deflection
Capacity
(in)
(lbs)
18
0.246
25
0.250
Figure 14
c. Verify that the V-belt is properly
aligned by checking pulley alignment.
Place a straightedge across both pulley
faces. The straightedge should make
contact with the pulleys in four places.
See Figure 15.
F232060
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Force Applied
(lbs)
5.6
5.6
Deflection
Span
Length
GV001IE1A
Maintenance
Motor
Drive Pulley
Figure 15
3. Remove back panel and check overflow
hose and drain hose for leaks.
4. Unlock the hinged lid and check the
supply dispenser hoses and hose
connections.
5. Clean inlet hose filter screen:
a. Turn water off and allow valve to
cool, if necessary.
b. Unscrew inlet hose and remove
filter screen.
c. Clean with soapy water and reinstall.
Replace if worn or damaged.
6. Tighten motor mounting bolt locknuts and
bearing bolt locknuts, if necessary.
7. Use compressed air to clean lint from
motor.
8. Clean interior of machine, both
basket and shell, by wiping with
a water-soaked sponge or cloth.
9. Use compressed air to ensure that all
electrical components are free of
moisture and dust.
Straightedge
Driven
Pulley
GV002BE1A
35