5.5.2. DIP switch 3 to 7
These DIP switches can be used to set:
- Battery charge voltage and Absorption time
- Inverter frequency
- Search mode
- AC input current limit 12A or 6A
ds3-ds4: Setting charge voltages
Absorption
ds3-ds4
voltage
ds3=off
14.4
ds4=off
28.8
(default)
57.6
ds3=on
14.1
ds4=off
28.2
56.4
ds3=off
14.7
ds4=on
29.4
58.8
ds3=on
15.0
ds4=on
30.0
60.0
Batteries with high antimony content can typically be charged with a lower absorption voltage
than batteries with low antimony content. (Please refer to our book 'Electricity on Board'
downloadable from our website www.victronenergy.com for details and suggestions about
charging batteries). Contact your battery supplier for the correct charge voltages and change
(with VE-configure) the voltage settings if required.
The default charge current setting is 75% of the maximum charge current. This current will be
too high for most applications.
For most battery types the optimal charge current is 0.1-0.2x the battery capacity.
ds5: Inverter frequency
ds6: Search Mode
ds7: AC input current limit
Store the settings by moving DIP switch 8 to 'on' and back to 'off'.
Float
Storage
voltage
Voltage
13.8
13.2
27.6
26.4
55.2
52.8
13.8
13.2
27.6
26.4
55.2
52.8
13.8
13.2
27.6
26.4
55.2
52.8
13.8
13.2
27.6
26.4
55.2
52.8
off = 50Hz
off = off
off = 12Amp
Absorption
Time
Suitable for
(hours)
Gel Victron Deep Discharge
8
Gel Exide A200
AGM Victron Deep Discharge
Gel Victron Long Life (OPzV)
8
Gel Exide A600 (OPzV)
Gel MK battery
AGM Victron Deep Discharge
Tubular plate or OPzS
5
batteries in semi-float mode
AGM spiral cell
Tubular plate or OPzS
6
batteries in cyclic mode
on = 60Hz
on = on
on = 4Amp
19