2. Profile setup
(see button combination)
2.2 Standby setup
• The standby time can be set in this setup.
– Turning the e-Drive
are set at the factory.
• Pressing the e-Drive
FAQ
• Machine switches off automatically
– The machine is automatically switched off after a set time with Standby mode (factory setting 40 minutes).
• Quality of the welding process is insufficient.
– Check drive speed, welding temperature and air volume
– Clean welding nozzle (9) with wire brush (33)
– Welding nozzle (9) is incorrectly set (see Operating preparation, page 23)
• The set welding temperature is not reached
– The air volume is set too high
– Insufficient voltage
• Startup mechanism not working
– Adjust drive sensor (see page 23)
• Device does not move straight
– Device positioning (see page 24)
• A star appears in the air volume display
– Blower is no longer on the specified curve, but instead in manual mode (see blower curve)
• Why is the air volume automatically adjusted when setting the welding temperature above 500°C ? (see blower curve)
– Achievement of the welding temperature is not ensured at too high air volume
allows the time to be set from 5 to 120 minutes. 40 minutes
will take you back to the Profile setup selection.
Error – Cause – Remedy
Blower curve VARIMAT V2
Welding temperature T [°C]
Manual
mode
Specified curve
>3680W
Specified curve
EU-Plug
Automatic
mode
31