1.5 Dip-Switches, jumpers
Description
DIP1 Radio mode
DIP2 Automatic closing time renewal
DIP3 State of automation at start
It indicates how the electronic panel consi-
ders the automation at the moment of the
start (or when supply comes back after a cut
off), whatever the real position of the auto-
mation.
DIP4 Electric lock release
Electric block function (24 V)
Warning: only with jumper EO=OFF and
with the BOX3SH and DOK-E type automa-
tion (see chapter 1.6).
DIP5 Pre-operation warning light (fixed at 3 s) (*) Disabled on opening. Enabled
DIP6 Selection 0-14
EO
Electric lock working
SO
Safety 1-8 function
FC
Limit switch mode selection
OM
Automation type
NIO
Electronic antifreeze system
FS
USO FUTURO
(* Factory settings)
1.6 Motor type setting
Automation type
Factory settings
Obbi3BH; ArcBH
Cubic30H; Cubic6H
Cubic30H + Cubic30LI (180°)
Luxo5BH
Box3SH
Arc1BH; Dor1BH
Facil3H
Dok-E
OFF /
(*) Step by step (1-5)
(*) 50%
(*) Open.
(*) Disabled.
Powered for the entire opening and
closing operation.
only with automatic closing with TC
greater than 3 secs.
(*) Flashing.
Powered for 2.5 s at the beginning of
the opening operation.
The opening of contact 1-8 with au-
tomation stopped enables opening
by means of controls 1-3, 1-5, 1-20
or radio remote control.
Limit switch stop.
Automation with one motor or with
two motors in parallel.
The output of motor 2 is the same
as that of motor 1: (36→33; 35→32;
34→31).
Cutting of the jumper automatically
activates the system which permits
motor running even at low tempe-
ratures. To properly operate, the
electric panel must be at the same
temperature as the motors.
S1
(N.C.)
(N.O.)
(N.C.)
(N.C.)
(N.C.)
(N.C.)
(N.C.)
(N.C.)
(N.O.)
15
ON /
Opens (1-3)
100%
Closed.
Automatic closing cannot be the
first control even if enabled.
Note: if automatic closing is not used
you should set DIP3=ON.
Enabled (advised position where
there is an electric lock).
Powered only with the automation
closed.
Enabled both during opening and
closing.
Courtesy light.
(*) Powered for 1.2 seconds at the
start of the opening manoeuvre.
(*) The opening of contact 1-8 with
automation stopped prevents any
operation.
(*) Slow down limit switch.
(*) Automation with two independent
motors.
(*) Disabled.
S2
S3
(N.C.)
(N.C.)
(N.C.)
(N.C.)
(N.O.)
(N.C.)
(N.O.)
(N.O.)
(N.C.)
(N.O.)
(N.C.)
(N.C.)
(N.O.)
(N.C.)
(N.C.)
(N.O.)
(N.O.)
(N.C.)
GB
S4
(N.C.)
(N.C.)
(N.C.)
(N.C.)
(N.C.)
(N.O.)
(N.O.)
(N.O.)
(N.C.)
VIVAH - IP1776