1. Localice el fallo:
faultmgmtsp> fmadm faulty
----------------- ------------------------------------- -------------- --------
Time
----------------- ------------------------------------- -------------- --------
2010-09-03/20:46:23 fa4a2f86-5156-4243-8e88-d6516db12970 SPT-8000-DH
Fault class : fault.chassis.voltage.fail
FRU
: /SYS/MB
(Part Number: 541-4197-04)
(Serial Number: 1005LCB-1025D40059)
Description : A chassis voltage supply is operating outside of the
allowable range.
Response
: The system will be powered off.
required LED will be illuminated.
Impact
: The system is not usable until repaired.
the system to be powered on until repaired.
Action
: The administrator should review the ILOM event log for
additional information pertaining to this diagnosis.
refer to the Details section of the Knowledge Article for
additional information.
faultmgmtsp> fmadm repair fa4a2f86-5156-4243-8e88-d6516db12970
faultmgmtsp>
2. Para reparar un error detectado por Oracle ILOM, utilice el comando fmadm
repair:
faultmgmtsp> fmadm repair fa4a2f86-5156-4243-8e88-d6516db12970
faultmgmtsp>
Nota – Es posible utilizar el nombre NAC (por ejemplo, /SYS/MB) o el UUID (por
ejemplo, fa4a2f86-5156-4243-8e88-d6516db12970) del error con el comando
fmadm repair.
72
Guía de administración de los servidores serie SPARC T4 • Noviembre de 2011
UUID
msgid
The chassis-wide service
ILOM will not allow
Severity
Critical
Please