MANUAL MODE
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the ON-
TIME switch in the 1, 5, or 20 position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.
D
B
ual
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or
20 minutes) then returns to dim mode.
Lamp Modes
There are three lamp modes (light turn-on effects) avail-
able when motion is detected:
• SECURITY ("NORMAL") - Light instantly comes on.
• BULBSAVER ("SOFT") - Light starts dim and grad-
ually increases to full brightness. Light gradually
dims to half-bright, pauses, and then continues dim-
ming to off when motion is no longer detected and
after selected ON-TIME.
• ALERTFLASH ("FLASH") - Light flashes on then
off twice before turning on full brightness.
INSTALLATION
CAUTION: Keep the sensor at least 2" (51 mm)
away from the bulbs.
1 Second
OFF then...
... back on.
Move ON-TIME Switch to
1, 5, or 20 minutes
Flip light switch off
for one second then
back on*
Timer
®
rite
CAUTION: To Avoid Fire Or Burn Hazards:
• Allow fixture to cool before touching. The bulb and
the fixture operate at high temperatures.
• Keep fixture at least 2" (51 mm) from combustible
materials. Do not aim at objects closer than 3' (1 m).
• Use only T4 100W (max.), G8 tungsten halogen
bi-pin 120 VAC bulbs.
For easy installation, select an existing light operated
by a wall switch for replacement. IMPORTANT: Do NOT
use with dimmers or timers.
For best performance, mount the fixture about 8 feet
(2.4 m) above the ground. NOTE: If fixture is mounted
higher than 8 feet (2.4 m), aiming the sensor down will
reduce coverage distance.
Wall Mount
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
For eave mount only:
1. Swing the sensor head towards the clamp screw
joint.
Clamp Screw
2. Then rotate the sensor head clockwise 180° so the
controls face down.
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
2
Eave Mount
Controls
Controls
Controls
203027-02