POINT A -
ELECTRIC CONNECTIONS
R1
J1
AERIAL
J2
LSC
LSO
COM
PED BUTT
L-N
J3
EARTH
J4
J5
RADIO
J6
D+ TEST
D+
D-
COM
K BUTT.
PHOT.
EDGE
J7
U - MOTOR
V-W - MOTOR
PROBE
J8
TRIMMER LOW SPEED
R1
TRIMMER TORQUE
R2
R2
J1
JP1
DO NOT REMOVE ANY JUMPER!
OTHERWISE THE OPERATOR WILL NOT WORK!
Radio Antenna
Close limit-switch that cuts off the motor in closing
Open limit-switch that cuts off the motor in opening
Limit-switch common contact
Pedestrian opening contact (NO)
Main power supply 230 Vac 50/60 Hz (120V/60Hz upon request)
Connection of the earth line
Built-in radio module (model CRX),
or connector for radio receiver RIB, 12 Vdc supply
12Vdc safety strip self-test power supply
Accessories power supply +12Vdc
Accessories power supply -12Vdc
Common contact (common line for all the command and safety inputs)
Single pulse contact (NO)
Photocells contact (NC)
Safety strip contact (NC)
Buzzer contact (12Vdc max 200 mA)
Flashing light (max 40W )
Motor common connection
Motor phase and capacitor connections
Temperature sensor cable connection PROBE (Code ACG4665 optional)
Electronic regulator for low speed on approach
Electronic torque regulator
J3
J4
J7
J6
J8
J2
J5
G G
B B