SN2005/TT
Rough-In Dimensions for Supplies and Drain
Notes
Maximum flow rate required to washfountain is 1 .5 GPM (5 .7 LPM) . Size
supply lines accordingly .
Supplies from Below: Stub up 2-1/2" (64) .
Supplies from Above: Supplies must be located on centers of dimensions
shown to pass through washfountain shroud and sprayhead .
Drain through floor: Stub up 3" (76) .
Supplies from Below or Through Wall
3-1/4" (83)
Remote mounting of transformers with 24VAC
electrical supply to washfountain is recommended.
UPC and IPC restrict the vertical distance from
the fixture outlet to the trap weir to not more
than 24" (610). Check state and local codes for
variances.
4
Type A
Off-line vent (P-Trap
supplied by Installer .)
Type H
Centrally rising vent (P-Trap
furnished with unit .) Use
for units with paper towel
Dispensers and/or shrouds .
Top View
4-1/2"
4-1/2"
(114)
(114)
H
C
Type H
5"
4"
(127)
Type A
(102)
10/20/2014
Key
1/2" Supply: Nominal Copper Tube
1-1/2" NPT Drain Stub up 3" (76) from
Floor
Conduit Location (Recommended)
Supplies from Above
Type B
Centrally rising vent (P-Trap
furnished with unit .) Use
for units with paper towel
Dispensers and/or shrouds .
Type O
Off-line vent (P-Trap
supplied by Installer .)
Top View
4" (102)
27/32" (21)
H
27/32" (21)
5"
(127)
C
1-3/16"
(30)
Bradley • 215-1760 Rev. L; ECN 14-00-007
Installation
(mm)
Type B
Type O