safety precautions and usage statements

IN-HOME USE AND HOSPITAL STANDARDS
Ergomotion adjustable bed bases are designed solely for in-home use . This
base was not designed as a hospital bed and is not designed to meet hospital
standards . Do not use this base with TENT TYPE oxygen therapy equipment or
near explosive gases .
For optimal safety and operation, plug bed base into a surge protector
(not included). The bed base should only be plugged directly into a
grounded wall outlet or surge protector (strongly recommended). Improper
connection of the equipment can result in the risk of electrical shock,
electrical file or faulty operation of this bed base. If the plug does not fit
your outlet, contact a qualified Electrician to install a suitable outlet.
ADDITIONAL SAFETY FEATURES
Casters (optional leg accessory) are equipped with locking wheels to prevent
unwanted movement . Even when locked and unable to roll, it is possible for
the casters to slide . Free release head and foot motors are designed to lower
the mattress by retracting only with gravity, never pulling downwards, which
minimizes pinch points.
LIFTING/LOWERING MECHANISMS
The lift/lower feature will emit a minimal humming sound during operation .
This is normal . During operation, the lift arm wheels make contact with the
platform support of the base . This contact may result in metal on metal
or metal on plastic contact . This applies slight tension on the moving
components and resonance is reduced to a minimum level . If excessive noise
or vibration is experienced, reverse the movement action (up or down) of
the base with the remote control . This should realign the base's activating
mechanisms to the proper operational position . In normal base operation, the
2
WARNING
ACOUSTICS
wheels, which allow the bed to maintain its distance from the wall, will make
contact with the steel platform supports of the base creating a contact noise .
When entering, exiting or shifting weight on the base, this contact noise may
be audible as the wheels make contact . This is normal .
MATERIALS
Ergomotion adjustable bases are constructed from various materials including
woods, metals, plastics and fabrics . Tension, pressure or movement applied
to the frame, platform or shroud through general use may create an audible
sound .
All Ergomotion adjustable foundations, depending on make and model, are designed and manufactured to perform and
function within designated quality control parameters. Bases are subject to meticulous and rigorous inspections during
the quality control process to ensure bases will operate within these standards during normal operating use.
TOLERANCE
Normal operating use is defined as the following:
-Adjustable foundation is to be operated with a mattress and load. Testing procedures require lifetime cycle
tests with up to 120kg distributed load.
The angle (designated "α" in figure 1) between the back section and the flat section for various configurations of the
mattress support platform shall be ± 3°, which translates to a tolerance of up to 1 ½".
The angle (designated "β" in figure 1) between the flat section and foot section for various configurations of the mattress
All Ergomotion adjustable foundations, depending on make and model, are
support platform shall be ± 3°, which translates to a tolerance of up to ¾".
When operating a "paired" split base setup there may be a time latency up to 1.5 seconds between each bases articulation.
designed and manufactured to perform and function within designated quality
Any adjustable foundation deemed to be within these allocated tolerances is considered to have met the manufacturer's
control parameters . Bases are subject to meticulous and rigorous inspections
quality control standards.
Blake Pettit
during the quality control process to ensure bases will operate within these
Quality Assurance Manager
Ph 805-979-3875
Fx 805-979-9399
standards during normal operating use. Normal operating use is defined
www.ergomotion.com
as the following: Adjustable foundation is to be operated with a mattress
and load . Testing procedures require lifetime cycle tests with up to 120 kg
Ergomotion Inc.
|
ph 1-888-550-3746
|
fx 805-979-9399
distributed load. The angle (designated "a" in figure 1) between the back
section and the flat section for various configurations of the mattress support
platform shall be ± 3°, which translates to a tolerance of up to 1 ½" .
Adjustable
Bed Tolerance
(α°)
(β°)
|
www.ergomotion.com