SLOWING DOWN, BLINKER AND
WARNING LIGHT
To set the slowing down, the blinker and the warning light
procede as follow:
1. Press and keep pressed the key P1 for 5sec (courtesy light
ON) and at the same time transmit with the key 3 of the
transmitter (the transmission must last 3 sec).
2. When the courtesy light switch off, stop the transmission
and release P1 key.
3. After 2 sec. the courtesy light visualizes the setted level with
the relative number of flashes. SEE CHART.
4. The courtesy light switch off for 2 sec. Then it goes on again
for 5 sec. waiting for a transmission.
5. Transmit (within 5sec) with the ideal key according to the
CHART.
6. The courtesy light switch off for 2 sec and therefore it
visualizes the new level setted with the relative number of
flashes. SEE CHART.
TX KEY
FLASHING N° DESCRIPTION
Key 1
1
Key 2
2
Key 3
3
Key 4
4
To correct any one of the parameters, restart from point 1.
BLINKER
The blinker blinks during the door movement as well as during
the whole automatic cycle OPEN-PAUSE-CLOSE.
WARNING LIGHT
The warning light shows in real time the state of the garage door:
STOP
light off
IN PAUSE
light always on
DURING OPENING the light flashes slowly (2 Hz)
DURING CLOSING the light flashes quickly (4 Hz)
Key 3
+
5 sec.
Slowing down
OFF
Blinker
OFF
Warning light
OFF
Slowing down
ON
Blinker
OFF
Warning light
OFF
Slowing down
OFF
Blinker
ON
Warning light
ON
Slowing down
ON
Blinker
ON
Warning light
ON
PRE-FLASHING AND PHOTOCELL TEST
To set the pre-flashing and the photocell test procede as follow:
1. Press and keep pressed the key P1 for 5sec (courtesy light
ON) and at the same time transmit with the key 4 of the
transmitter (the transmission must last 3 sec).
2. When the courtesy light switch off, stop the transmission
and release P1 key.
3. After 2 sec. the courtesy light visualizes the setted level with
the relative number of flashes. SEE CHART.
4. The courtesy light switch off for 2 sec. Then it goes on again
for 5 sec. waiting for a transmission.
5. Transmit (within 5sec) with the ideal key according to the
CHART.
6. The courtesy light switch off for 2 sec and therefore it
visualizes the new level setted with the relative number of
flashes. SEE CHART.
TX KEY
FLASHING N° DESCRIPTION
Key 1
1
Key 2
2
Key 3
3
Key 4
4
WARNING: The control unit carries out a test to check
if there is the photocell as well as its correct operation before
each movement.
To correct any one of the parameters, restart from point 1.
30
Tasto 4
+
5 sec.
Pre-flashing OFF
Photocell Test OFF
Pre-flashing OFF
Photocell Test ON
Pre-flashing ON
Photocell Test OFF
Pre-flashing ON
Photocell Test ON