4.1 Controls
GB
Control
1
5
N.O.
1
8
N.C.
1
9
N.C.
AUX
4.2 Output and accessories
Output
1
+
24 V= / 0,3 A (nominal)
0
-
24 V= / 0,5 A (peak)
0
14
BAT
0
15
0
15
8,2 Ω / 5 W
1
13
GLOBE - IP1839
Function
STEP-BY-STEP
OPEN WITH
AUTOMATIC CLOSING
OPEN WITHOUT
AUTOMATIC CLOSING
REVERSAL
SAFETY CONTACT
STOP
Value
Accessories power supply. External accessories power supply output.
24 V= / 30 W max.
Flashing light (LAMPH). It is activated both on opening and on closing.
24 V= / 25 W
Courtesy light. It is activated for 3 minutes on every opening and closing command.
Battery operation. An optional battery kit is available (BATK1). With power supply
on, the batteries are kept charged. Without power supply, the panel is powered by the
batteries until power returns or until battery power falls below the safety threshold. In
this latter case, the control panel goes off.
Attention: to allow recharging, the batteries kit must always be connected to the control
panel. Periodically, verify the battery efficiency.
Note: the operating temperature of the rechargeable batteries is +5°C/+40°C
approximately. To ensure proper battery operation rooms should be air-conditioned.
24 V= / 1,2 A max
Electric lock. It is avtivated at each opening command given from closed door.
12 V / 15 W
Electric lock. With a 12 V electric lock, connect the 8,2 Ω / 5 W resistor. It is activated
at each opening command given from closed door.
24 V= / 3 W
Open door light (analogic output). Light comes on and only goes off when door is
closed.
With DIP1=OFF the closure of the contact activates the sequence: open-
stop-close-open.
Note: if automatic closing is enabled, the STOP is not permanent but at a
time that is set by TC.
With DIP1=ON and the automatic closure on, the closure of the contact
activates an opening operation.
With DIP1=ON and TC=MAX, the closure of the contact activates an ope-
ning operation.
With the automation idle, the closure of the contact performs the operation
opposite to that prior to the stop.
The closing of the contact during the closure manoeuvre causes the move-
ment to invert (re-opening).
The opening of the contact causes the movement to stop and the automatic
closure to be disabled.
Resetting the command, the door remains still until a 1-5 command or a
radio command is received.
The control panel has one space for coupling board, type radio receivers,
magnetic loops etc.
The coupling board working mode is selected by DIP1.
Warning: the plug-in cards must be inserted and removed with the power
supply disconnected.
Description
22
Description