4.

CHECKING AND ADJUSTMENT

With the wing in movement, check the push force at the
top of the wing with a dynamometer. This must not exceed
15 kg (147 N). If it does, adjust the operating force on the
electronic controller (see advanced programming in the
Electronic controller Manual).
!
Warning
Once the adjustment has been made, use the dynamometer
again to check that the push force does not exceed the specifi ed
value. If it is still too high, adjust the push force once again.
If the push force needed for the wing movement is still too
high, check the mechanical components for jamming,
check that the gate is vertical (use a plumb line) and check
that the wing moves smoothly. On the basis of the risk
assessment made earlier, install any presence detection
devices necessary (e.g. photocells, sensors).
Information
Compliance with Machinery
Directive 98/37/EC. Once you have installed the equipment,
you must compile a Declaration of Conformity and a Scheduled
Maintenance Plan in compliance with the Machinery
Directive and then hand over copies of these documents
to the user. For maintenance instructions, see par.5.2.
5.

OPERATOR - PERMITTED USES

The automation is designed for use on twin wing gates for
residential use, with a maximum number of 50 opening/
closings per day.
Use with the wing sizes recommended in the technical data
of the product.
Carefully read the general instructions provided.
The operator is non-reversible, so if it is not working or has
no power supply, the gate wing will not be able to move
unless the motor is released (see par. 5.1).
5.1
Motor release for manual gate movement
(EMERGENCY RELEASE)
In the event of a power or battery failure, you can move the
gate manually by fi rst releasing operator.
!
Warning
To release the motor, you must
be on the inside of the gate. If there is no power supply, you
should enter through another entrance.
Releasing the motor
Insert the release Allen key and turn it through 180° (Fig.17)
(the direction, clockwise or anticlockwise, is unimportant; it is
important that you turn the key through 180°).
Move the gate slowly. Do not push, pull or force it.
SPACE RESERVED FOR INSTALLER
PLEASE GIVE A COPY OF THIS PAGE TO THE USER
OPERATOR FOR SWING GATES
RAIDER 2500
Relock the motor
To reslock the motor:
Insert the release Allen key and turn it through 180° (Fig.17)
(the direction, clockwise or anticlockwise, is unimportant;
it is important that you turn the key through 180°).
Move the gate slowly by hand without forcing it until you hear
the metallic indicating that the mechanical drive has engaged.
5.2

Scheduled maintenance

You should ask the company that installs the automation
provide a scheduled maintenance plan in compliance with
the regulations for this type of equipment. The maintenance
recommended by Aprimatic S.p.A. for automation components
is as follows:
Do not throw away old batteries with domestic waste. Dispose of old
batteries using the old battery containers provided at sales outlets.
Batteries are consumables and as such are not covered by
the guarantee.
The maintenance recommended by Aprimatic S.p.A. for the
lock parts and the electrical system is listed in Tab.2.
Fig.17
operation
Check the lubrication of the front and rear
mounting pivot of each operator.
Check that the manual emergency
release is working properly.
Check that the operator mechanical limit
stops are working effi ciently.
Check the hinges on the gate and ensure
they are properly lubricated.
Check the strength and stability of the
wing structure. Tighten it where necessary.
Reinforce the structure where necessary.
Clean the striker plate of the electric lock
(where installed).
40059 Villa Fontana di Medicina - Bologna - Italia
Telf. +39 051 6960711 - fax +39 051 6960722
info@aprimatic.com - www.aprimatic.com
- 21 -
Tab.2
Aprimatic S.p.A.
via Leonardo da Vinci, 414
frequency
Every 6
months
Every 6
months
Every 6
months
Every 12
months
Every 12
months
Every 6
months

Publicidad

Tabla de contenido
loading

Tabla de contenido