Take hold of the new lamp taking care not to place your fingers outside the cap.
14
(if you do, clean the lamp with a soft cloth and some methylated spirits).
15
16
17
18
UV_NM-GB.doc
Marque, Modèles et Brevets déposés - Produits exclusifs
Clean the quartz sleeve with acid or white vinegar or replace it if necessary.
With a finger inside the sleeve, insert the quartz sleeve into the equipment up
to its housing at the bottom of the reactor.
The quartz should protrude slightly, it should not be dropped right to the
bottom.
If the quartz is correctly positioned in the base, when you press it, it feels
flexible (pneumatic effect).
Change the quartz seals:
(Put a new seal at each change of lamp)
● lubricate the seal using food grade grease,
● position it around the sleeve,
● push it fully home in its housing using your nail (do not use tools).
Replace the flat washer.
Re-tighten the nut by hand, tightening it normally.
Put the installation back in pressure before the reassembly of lamps and
check that there is no leakage in the quartz sleeve.
Fully engage the lamp in the quartz sleeve.
Refit the support from the cover.
Reconnect each lamp connector. (Do not force the connector into place:
There is a specific connection direction) and clip the connector onto the
stainless steel nuts.
Reconnect the grounding terminal lug.
Refit the cover.
Check the calibration of the UV-C ray measurement cell.
(See chapter MANUAL OF THE MONITOR).