OPERATIONAL MODES

The control units may be connected to motors with either mechanical limit switches
or electronic limit switches.

NOTES ON ADJUSTMENT OF THE LIMIT SWITCHES

To adjust the limit switches refer to the motor manual.
- MECHANICAL LIMIT SWITCH WITHOUT SAFETY DEVICE
Connect the control unit. Move the motor in the desired direction. Turn the motor's
adjustment screws to bring the blind to the desired position.
- MECHANICAL LIMIT SWITCH WITH SAFETY DEVICE (closing force adjustment)
When there are safety devices installed (lock down hangers, physical stops or
similars), it is possible to adjust the limit switch at the closing force adjustment.
Connect the control unit. Move the motor in the desired direction. Turn the motor's
adjustment screws to bring the blind to the mechanical stop. Stop the motor and
again turn the motor adjustment screws in the + direction three (3) turns, adjust
the mechanical limit stop position of the motor beyond the mechanical stop.
- ELECTRONIC LIMIT SWITCH (control panel)
With Plug & Play motors no limit switch adjustment is required, so the control unit
may be connected immediately.

MOVING THE MOTORS WITH OVERRIDE DEVICE

This control unit is specifically suited for motors with mechanical limit switch and
manual override device.
After a safety action movement of the blind, the control unit resets the proper
positions upon reaching a valid limit switch position.