line : By pressing the
button, the fourth line will display successively :
Regen.Time 00240s :
regeneration time regulated at 240s.
Password : 00000:
enter for acces to change pressurusation time on.
Pressur Time 00060s :
pressurisation time regulated to 20 at 60s.
Hours Meter 0000h :
hour meter for dryer operation.
number of remaining hours in 'operation /48H' phase (countdown).
Forced Oper. 48h :
To allow to have a good atmospheric pressure upstream, the dryer begins with
Start Delay 00015s :
a delay of 15 when we give the order to work on " auto operation " or " forced
operation " to the dryer.
If there was no operation order during 7200 (2 hours) then the dryer is started up
Inacti.Time 07200s :
during 2 cycles. This time is adjustable to 900 (15min) at 10800s (180min / 3h).
M3017VK EN :
Program N°, where K is the version.
If the
button is not activated during 2 minutes, the fourth line will automatically turn blank.
Restoring of the hour meter by pressing
+
7.

ELECTRICAL DIAGRAM for AD5xxx without Cyclone filter

See ANNEX
8.

SPARE PARE LIST

See ANNEX
518718-12
SEC A / 1A / 2A / 7OX / 7HC –AD 5xxx
buttons at the same time.