4.3.1 Electrical specifications of the installation

MOD.
T-OEM-350
(DD)
T-OEM-350 UK
T-OEM-400
(UK / UK B)
T-OEM-400
(DD / B)

4.3.2 Voltage Configuration of the machine

The voltage configuration of the machine is stipulated on the nameplate (230V 1N~50Hz/60Hz). This
configuration cannot be changed, therefore it is essential that the mains voltage of the premises
where the machine is to be installed is confirmed prior to purchase. Fig. 6

4.4 Hydraulic connection

The new hoses supplied with the appliance should be used (do not reuse old hoses).
Before connecting the machine to the water supply, the water quality should be tested.
Recommended water quality:
Water temperature (T):
If the water hardness is more than 10 ⁰fH (French degrees), a descaler must be installed.
In addition to water quality, the pressure of the mains water supply must be considered. This is
important to ensure the machine operates correctly.
Required water pressure:
DYNAMIC
PRESSURE
If the water pressure is higher than the recommended pressure, a pressure regulator must be
mounted at the output Fig. 2. If the mains water pressure is lower than the recommended pressure,
a pressure pump should be mounted at the mains water supply Fig. 3. It is not necessary to install a
pressure pump in the W models.
Fig. 2. Direct connection of water input hose.
Fig. 3. Pressure pump connection.
S → SHUT-OFF COCK
E → ELECTROVALVE
The following requirements are necessary for the correct hydraulic installation of the machine.
5
31mm in diameter and must be installed in accordance with AS/ NZ3500.2 (drainage) by means of coupled
connection to a DN50 or larger pipe
6
For Australia, watermark certified inlet hose and backflow prevention device. Must be installed in
accordance with AS/NZS3500.1 (water service supply) including installation of the supplied backflow
prevention device.
SUPPLY
VOLTAGE
230V 1N~ 50/60Hz
max. 60 ⁰C
pH:
6.5 - 7.5
Impurities:
Ø < 0.08 mm
Chlorides:
max. 150 mg/l
Cl:
0.2 - 0.5 mg/l
Min.
bar
kPa
Kg/cm
2
200
F → FILTER
B → ELECTRIC PRESSURE PUMP
The hydraulic circuit must be fitted with a valve to shut-off the water supply.
Check that the mains pressure is within the range indicated above.
To optimise the working of the machine, the manufacturer recommends that the water
temperature at the machine intake is within the following range.
Cold H
O
2
5 ⁰C < Tª < 25 ⁰C / 41 ⁰F < Tª < 95 ⁰F
If using hot water, the water temperature must not exceed 60 ⁰C / 140 ⁰F.
All the machines should have a ¾" screw-on connection.
MAX ELECTRIC
POWER
3,1kW
2,7 kW
3,1 kW
Total water hardness:
Conductivity:
2
psi
bar
2,03
29
3,5
5
40 ⁰C < Tª ≤ 60 ⁰C / 122 ⁰F < Tª < 140 ⁰F
MAIN SWITCH
AMP.
FUSE
13,5 A
20 A
12 A
16 A
13,5 A
20 A
5 – 10 ⁰fH (French degrees)
7 – 14 ⁰eH (English degrees)
9 – 18 ⁰dH (German degrees)
400 - 1,000 µS/cm
Max.
2
kPa
Kg/cm
350
3,56
H → WATER HOSE
Hot H
O
2
NET
WEIGHT
34 Kg
41 Kg
psi
50,76
6