ELECTRICAL CONNECTIONS - WIRING DIAGRAMS

The boiler must be connected to an earthed, single-phase 230V-50 Hz mains supply by means of a three-wire
cable, ensuring that connections to the LINE and NEUTRAL terminals are made correctly.
A bipolar switch must be used with contacts opening to at least 3 mm.
The power lead must only be replaced by another with the following characteristics: "HAR H05 vv-F" 3 X 1.00
mm
2
. (You are strongly advised to use original LAMBORGHINI accessories and spare parts only).
Installation must be made in compliance with safety REGULATIONS IN FORCE.
Make a good earth connection.
Voltage
Frequency
V
230
To gain access to the electrical panel which houses the power supply terminal block and any connection to a
room thermostat, proceed as follows:
Disconnect the boiler power
supply
Undo the two grating screws
(fig. 1)
Undo the four shell attachment
screws A (fig. 2)
Remove the shell (fig. 3)
To gain access to the electrical
and electronic components
loosen screws B and pull the
entire panel outwards (fig. 4).
Tilt it downwards and undo the
screws C on the cover D
fig.3
Absorbed power
Hz
50
B
kW
VELA X N 24
0,150
fig.1
B
fig.4
Protection
Noise level
index
VELA X N 24
IP
X4D
A
A
D
C
30
dB (A)
46
fig.2
fig.5