MULFUNCTIONS AND ADJUSTMENTS
Should the boiler shut down it must be reset by rotating function selector to the reset position A.
Legend:
On
Off
JP1
On
LPG
On
(post-circ. off)
JP2
heating
Resistor R150 cut, floor heating temp. set to 30/40°C.
Resistor R150 uncut, heating temperature 35/80°C.
RLA
Slow ignition adjustment
Increase
R max
Max. heating power adjustment
Increase
Timer
Boiler timer adjustment
Increase
Constant light: Ignition
shutdown
Fast flashing light: TST
shutdown
Off
METHANE
Off
post-circ.
on 2.5 minutes
A
Constant light: No water
circulation or modulating coil
Fast flashing light: Sensor
fault
Slowly flashing light: Air
pressure switch (MBS)
RLA
Timer
JP2
Rmax
JP1
X