Pump Connection (5.1/5.2/5.3); Humidity Sensor Connection (6.3/6.4) - Alpha IP MIOB 21001-XX Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 61
PE
PE
L
1.1
1.2
2.1
L
N
L
N
Heating
Cooling

6.5 Pump connection (5.1/5.2/5.3)

Terminal 5.1/5.2/5.3 is a switching relay as potential-free change-over switch. For the standalone var-
iant, only the pump is connected. If the Alpha IP Access Point is operated using the Alpha IP app, the
terminal can also be used for air humidity sensors or for the CO pilot.
(see fig. 4 page 3)

6.6 Humidity sensor connection (6.3/6.4)

Terminal 6.3/6.4 (IN2) is an input for potential-free contacts. For the standalone variant, only the hu-
midity sensor is connected. If the Alpha IP Access Point is operated using the Alpha IP app, the terminal
can also be used for temperature limiters (TL) or as external clock (ECO). A Homematic CCU 2 allows to
control all inputs and outputs individually.
Humidity sensors (to be provided by the customer) serve for dewing protection in the cooling mode.
As soon as the humidity sensor is triggered, the blue C/O LED of the MIOB and the symbol
in the room control unit LCD flash. The pump switches off and all FAL drives are closed.
L
N
N
1▼
L▲
2.2
3.1
3.2
4.1
4.2
2▼
L▲
1▼
5.1
5.2
5.3
Connections
21

Publicidad

Tabla de contenido
loading

Productos relacionados para Alpha IP MIOB 21001-XX

Este manual también es adecuado para:

Miob 21001

Tabla de contenido