6.9 Temperature limiter connection (Access Point variant)

The Access Point variant allows the operation of a temperature limiter (1). The temperature limiter can
be connected to terminal 6.1/6.2 (IN1) as well as to the terminal 6.3/6.4 (IN2). The temperature limiter
switches off the pump if too high flow temperatures for the floor heating are detected. If the TL input
is switched, the base station shuts down all actuators automatically.
(see fig. 6 page 3)

7 Commissioning

Please read this section completely and carefully prior to commissioning.
The Multi-IO Box is taught in for standalone operation directly to the Alpha IP base station (FAL
21001/41001) or optionally to the Alpha IP Access Point (HAP 21001). For the variant with Alpha IP
base station, the subsequent configuration is done with the room control unit Display (RTD 61001) or
the Alpha IP room control unit Display S (WTHP 61001); for the Alpha IP Access Point variant, configu-
ration is done with the Alpha IP app. The device is preconfigured for the standalone solution.

7.1 Teach-in without Alpha IP Access Point (stand-alone operation)

Keep a minimum distance of 50 cm between the devices for teaching-in.
The teach-in process can be interrupted shortly pressing the teach-in key again. This will be
confirmed by a red illumination of the LED of the Multi-IO Box.
For the integration into an existing system, first the Alpha IP base station and subsequently the
Alpha IP Multi-IO Box must be brought into teach-in mode.
For a standalone operation, the teach-in of the Alpha IP Multi-IO Box station must be performed via the
Alpha IP base station (FAL 21001/41001). Teach-in the device as follows:
1. Press the System key at the Alpha IP base station repeatedly, until the LEDs of all heating zones light
up in green.
2. Press the System key (A) of the Alpha IP base station for 4 seconds, until the LED of the System key
flashes rapidly in orange.
9 The teach-in mode is active for three minutes.
3. Press the System key (A) of the Multi-IO Box for 4 seconds, until the LED of the System key flashes
in orange.
The System key LED will light up in green after a successful teach-in process. The process must
be repeated if the LED lights up in red.