Maintenance - Domnick Hunter PNEUDRI MiDAS Manual De Instrucciones

Tabla de contenido

Publicidad

4.0 MAINTENANCE

Daily
Ensure the yellow 'power on' LED and the green 'correct operation' LED are
illuminated.
Weekly
Check dryer seals, fittings and pipe work for air leaks.
Ensure correct operation of inlet filtration condensate drainage.
The Combination desiccant / after-filter cartridges have a finite life dependent upon
operating conditions.
Cartridge status is indicated
Power On
Power On
Cartridges require changing and audible alarm will sound every 6 seconds.
NOTE: Temporary resetting of the alarm to prevent nuisance noise is possible after
alarm has sounded for the first time. This is done by depressing once the reset button
located inside the control enclosure, accessed by removing the black insert on the
side. The alarm will be muted for a 24 hour interval until the dryer has been serviced
and the reset sequence completed.
Servicing of the dryer must only be carried out by domnick hunter personnel or trained
domnick hunter service agents.
*
Cartridges will require changing in 500 hours.
*
!
*
*
!
12
Cartridge Wear
Service Required

Publicidad

Tabla de contenido
loading

Tabla de contenido