2.3 ELECTRICAL DETAILS
Only competent qualified electricians must work on dryer circuitry.
Check the rating plate for power supply requirements.
Correct isolator switches must be provided at a safe and accessible point near to the
dryer.
The dryer must be provided with a live, neutral and earth ground.
Connect power to the dryer (via the mains cable gland *) at the fused terminal block
mounted on the small base plate located under the enclosure. Four screws retain the
base plate.
A T500mA fuse is fitted as standard.
*For CSA / NPT dryers, the cable gland is replaced by a conduit entry aperture.
230V, 50Hz
230V, 50/60Hz
115V, 60Hz
115V, 50/60 Hz
T500mA
Brown
Blue
Live
Earth
Neutral
6
ground