Maintenance
The power supply must always be completely discon-
nected before performing any maintenance work on the
device.
Clean the device and the ventilation slits with a dry and fluff-
free cloth.
Disposal
The device must be disposed of in line with the administra-
tive regulations of the respective country in which it is used.
National regulations and laws (in Germany, for example, the
End-of-life Vehicle Regulation) must be observed.
Technical data
Power supply
AC voltage 230 V / 50 Hz, single-phase
Range approx. 205 V – 265 V / 45 – 65 Hz
Output
Sustained short-circuit protection
Idle-proof
Output voltage
12 V DC + 6 % (< 0.05 % / °C)
Output power
450 W at 20 °C, above this, automatic power reduction
Residual ripple
< 0,18 Vpp
Storage temperature
-20 – +80 °C
Air humidity
5 – 95 % without thawing
Noise
< 10 dBA (at a distance of 1.5 m)
Dimensions (L x W x H)
360 x 220 x 103 mm
Weight
2.5 kg
The right to effect technical modifications is reserved!
8
Troubleshooting
Error
Connected consumers do
not work.
The maximum output
current is not achieved.
If these measures do not solve the problem, please
contact the Truma Service Centre.
Rectification
–
Check all connections are
correct.
–
Pull out the female device
plug to disconnect the
device from the 230 V AC
voltage mains. Wait 15 s –
connect the female device
plug to the device again.
–
Check all fuses and the
mains supply connection.
–
The device is too warm,
ensure better ventilation
of the device.