DOR - Indicación del estado de las puertas
--DOR,a,hhmmss.ss,aa,cc,xxx,xxx,a,a,c--c*hh CR> LF>
1
2
3 4
1. Message type
S=Status for section: the number of faulty and/or open doors reported in the division specified in
field 4 and 5. The section may be a whole section (one or both of the division indicator fields are null) or
a sub-section. The status S is normally transmitted at regular intervals.
E = Status for single door. (E may be used to indicate an event).
F = Fault in system: Division indicator fields defines the section when provided.
2. Event time
Time when this status/message was valid.
3. Type of door monitoring system
The field is two characters, see table below.
4. First division indicator
First division indicator where door is located.
5. Second division indicator
Second division indicator where door is located.
6. Door number or door open count
This field is three fixed numeric characters. When the message type field is E this field identifies the
door. When message type fields is S this field contains the number of doors that are open or faulty.
When the message type field is F this field is null.
7. Door status
When the message type is S or F this field shold be a null field. When the message type field is E.
this field is specified by the following:
O = Open C = Close F = Free status (for watertight door) X = Fault (door status unknown)
8. Water tight door switch setting
This field includes a single character specified by the following:
O = Harbour mode (allowed open) C = Sea mode (ordered closed)
9. Message s description text
Descriptive text/door tag. If a door allocation identifier is string type, it is possible to use this field instead
of the above door allocation fields. The maximum number of characters will be limited by the maximum
sentence length and the length of other fields.
Tipo de sistema de supervisión de
puertas
ID
Categoría del sistema
WT
Puerta estanca al agua
WS
Puerta semiestanca al
agua
(protección contra salpica-
duras)
FD
Puerta de incendios
HD
Puerta del casco
OT
Otras
DPT - Profundidad
$--DPT,x.x,x.x,x.x*hh<CR><LF>
1
2 3
1. Water depth relative to the transducer, in meters (0.00 to 99999.99)
2. Offset from transducer, in meters (-99.99 to 99.99)
3. Minimum range scale in use (no use)
5 6 7 8 9
Primer indicador de
división
Número de mamparo de
puerta estanca al agua/
número de marco
Número/letra de la zona
También se puede utilizar
para identificar el sistema
de control y supervisión
principal.
Número indicador de puer-
ta/número de marco
Como arriba
APÉNDICE 4 INTERFAZ DIGITAL
Segundo indicador de
división
Número de cubierta
Número de cubierta o número
de bucle del sistema de con-
trol, u otro indicador de división
del sistema de control, en
función de lo que sea más ade-
cuado para el sistema
Número de cubierta
Como arriba
AP-15