Electrical Requirements - Sub-Zero UC-15IPO Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SI T E P R E PA R AT I ON

Electrical Requirements

Installation must comply with all applicable electrical codes.
Although it can be located anywhere on the back wall, it
is recommended that the electrical supply be placed in an
adjacent cabinet or in the lower right of the opening. Refer
to the illustration below. A separate circuit servicing only this
appliance is required.
Model UC-15I(P)O is designed and safe for use in outdoor
applications. When installed outdoors, a ground fault circuit
interrupter (GFCI) is required to reduce the risk of electrical
shock. A GFCI is not recommended for use with the indoor
model and may cause interruption of operation.
EL EC T R IC A L R EQ UI R EM ENT S
Electrical Supply
Service
Receptacle
E
E
E
Electrical supply location
115 VAC, 60 Hz
15 amp dedicated circuit
3-prong grounding-type
CAUTION
The outlet must be checked by a qualified electrician
to be sure it is wired with the correct polarity. Verify the
outlet is properly grounded.
WARNING
Do not use an extension cord, two-prong adapter, or
remove the power cord ground prong.
subzero.com | 5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Uc-15io

Tabla de contenido