SI T E P R E PA R AT I ON
Plumbing Requirements
Installation must comply with all applicable plumbing codes.
The water supply line should be located as shown in the
illustration below. The water supply line should be con-
nected to the house supply with an easily accessible shut-
off valve. Do not use self-piercing valves.
A reverse osmosis system can be used provided there is
constant water pressure of 20–80 psi
the unit at all times. A copper line is not recommended for
this application.
PL U M BIN G RE Q U IR EMEN T S
Water Supply Line
Water Pressure
Excess Water Line for Connection
IC E MA K E R DR A I N
The ice maker can be ordered with or without a drain pump.
Models without a pump will drain water by gravity.
A drain must be installed.
The drain and inlet water tubes must be plumbed before
connection to the ice maker. For the gravity drain, horizontal
drain lines must have a
will likely be required between the unit and drain. A stand
pipe with a trap below is acceptable for the drain.
8"
(203)
1
/
"
2
( 13 )
LOCATION OF
WATER LINE
TOP VIEW
Water supply location
1
15
/
"
4
min (387)
ROUGH
OPENING WIDTH
6 | Sub-Zero Customer Care 800.222.7820
LOCATE
POSITION OUTLET
ELECTRICAL
supplied to
(1.4–5.5 bar)
1
/
" OD copper, braided stain-
4
less steel, or PEX tubing
20–80 psi
(1.4–5.5 bar)
1
/
"
per 12"
fall. An air gap
(6)
(305)
4
24"
(610)
ROUGH
OPENING
DEPTH
1
34
/
"
2
(876)
ROUGH
OPENING
HEIGHT
5
33
/
"
8
(854)
MINIMUM
HEIGHT
Preparation
CAUTION
Before moving the unit into position, secure the door
closed and protect any finished flooring.
Uncrate the unit and inspect for damage. Remove the wood
base and discard shipping bolts and brackets. Remove and
recycle packing materials. Do not discard the kickplate and
hardware.
Use an appliance dolly to move the unit near the opening.
If the unit has been on its back or side, it must stand upright
for a minimum of 24 hours before connecting power.
36"
(914)