[074] Key Options
Default
Option
I____I
1
[F]ire Key Enabled
ON
I____I
2
[A]uxiliary Key Enabled
ON
I____I
3
[P]anic Key Enabled
ON
I____I 4-8 For Future Use
OFF
[076] First Keypad Options
Default
Option
I____I
1
Display Code when Programming
ON
I____I
2
Local Clock Display ON
ON
I____I
3
Local Clock Displays 24-hr Time
OFF
I____I
4
Auto Alarm Memory Scroll Enabled
ON
I____I
5
Local Display of Temperature ON
OFF
I____I
6
Bypass Options prompt ON
ON
I____I
7
For Future Use
OFF
I____I
8
Auto-Scroll Open Zones ON
OFF

[077] Second Keypad Options

Default
Option
I____I
1
Chime Enabled for Zone Openings
ON
I____I
2 Chime Enabled for Zone Closings
ON
I____I
3
5th Terminal is Keypad PGM Output
OFF
I____I
4 Language Selection Enabled Language Selection Disabled
ON
I____I
5 Power LED Enabled
OFF
I____I
6 Power LED indicates AC present
ON
I____I
7
ON
Alarms always Displayed When Armed
I____I
8
Low Temperature Warning Enabled
OFF
[080] PGM Terminal 1
Default: 01 I
I
1-14 Follow PGM Output Number, 15 Local PGM Pulse , 16 Local PGM Toggle
I
[082] Local PGM Output Pulse Activation Time
Minutes (Valid Range 00-99)
Default: 00 I
I
I
Seconds (Valid Range 00-99)
I
Default: 05 I
I
[101]-[108] Partition Labels
ex. For Partition 1 enter section [101], for Partition 2 enter section [102] etc.
Partition
Section
I
I
I
[101] to [108]
1 to 8
I
I
I
NOTE: Partition 1 Label is also used as the System Label
ON
OFF
[F]ire Key Disabled
[A]uxiliary Key Disabled
[P]anic Key Disabled
ON
OFF
Display "Xs" when Programming
Local Clock Display OFF
Local Clock Displays AM/PM
Auto Alarm Memory Scroll Disabled
Local Display of Temperature OFF
Bypass Options prompt OFF
Auto-Scroll Open Zones OFF
ON
OFF
Chime Disabled for Zone Openings
Chime Disabled for Zone Closings
5th Terminal is Keypad Zone Input
Power LED Disabled
Power LED indicates AC absent
Alarms not Displayed When Armed
Low Temperature Warning Disabled
Label
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
[120]-[151] Command Output Labels
Default: "Command_O/P_1" - "Command_O/P_4"
For Partition 1 Command O/P 1 to 4 enter [120] to [123] For Partition 5 Command O/P 1 to 4 enter [136] to [139]
For Partition 2 Command O/P 1 to 4 enter [124] to [127] For Partition 6 Command O/P 1 to 4 enter [140] to [143]
For Partition 3 Command O/P 1 to 4 enter [128] to [131] For Partition 7 Command O/P 1 to 4 enter [144] to [147]
For Partition 4 Command O/P 1 to 4 enter [132] to [135] For Partition 8 Command O/P 1 to 4 enter [148] to [151]
Section Part
[120]-[151] 1 to 8
[201]-[264] Door Chime Sound Programming
You can program the keypad to make up to four different door chime sounds for individual zones.
ex. For Zone 1 enter section [201], for Zone 2 enter section [202] etc.
Default
I____I
ON
I____I
OFF
I____I
OFF
I____I
OFF
I____I 5-8
OFF
[994][✱] Initiate Global Keypad Chime Broadcast
[995][✱] Reset Keypad Options to Factory Default
[996][✱] Label Default
[997] View Software Version
[998][✱] Initiate Global Label Broadcast
[999][✱] Reset Keypad EEPROM to Factory Defaults
Keypad Display Symbols
Ready Light (green) – If the Ready light is on, the system is ready for arming.
1
Armed Light (red) – If the Armed light is on, the system has been armed successfully.
2
I
I
I
I
System Trouble – Indicates that a system trouble is active.
I
I
I
3
I
AC – Indicates that AC is present at the main panel.
4
Cmd.
Output
I
I I
I
I
I
I I
1 to 4
I
I I
I
I
I
I I
Option
ON
1
6 Beeps
"Bing-Bing" Sound
2
"Ding-Dong" Sound
3
4
Alarm Tone
For Future Use
Label
I
I
I
I
I
I
I
I
I
I
I
I
I
I
OFF
Disabled
Disabled
Disabled
Disabled
1
2
3
4