INDICATIONS ON THE DISPLAY (D1)
alarm caused by two mechanical travel limits being acti-
vated together
memorised parameter error
time programming mode block
( caused by: TB, FTC_I, FTC_S )
defi ning the system confi guration
waiting period between successive programming stages
deceleration time setting (value 1)
level 1 electrical input sensor
work time programming
opening stage
block
reclosing pause (only if enabled)
closing stage
updating the electrical input monitoring system
MANUAL OPERATION MODE
This can be used to close the door (or open it) under the direct
control of the operator (in this mode the security devices are
excluded as well as the electrical input monitoring system, only
the blocking button "TB" and the closing and opening direction
photoelectric cells are operational FCA/FCC). The aim of this
command is to make installation easier and to allow you to have
the door completely closed before starting the programming
procedure. In this mode the Led "L3" (marked "UPL") will
remain lit.
• Closing manoeuvre
This is obtained by pressing the button "SEL".
The motor will block in the closing direction due to:
- releasing the "SEL" button (takes you out of the "manual
operation mode").
- activating the blocking button "TB": to move the door again you
must fi rst release the "SEL" button and then press it again.
- activating the closing direction travel limit (if installed): pressing
the "SEL" button will not cause the door to close, but it will
switch the night light on.
• Opening manoeuvre
This is obtained by pressing the button "SEL", and then the
"PROG" button straight away.
The motor will block in the opening direction due to:
- releasing both buttons (takes you out of the "manual operation
mode").
- activating the blocking button "TB": to move the door again you
must fi rst release both buttons and then press them again.
- activating the opening direction travel limit.
• Travel direction inversion
If the door is closing: to enable an opening manoeuvre:
- press the "PROG" button
If the door is opening: to enable a closing manoeuvre:
- release the "PROG" button
• Night light
The night light remains on all the time while in the "manual
operation mode"; it also lights up when an opening or closing
command is given but the travel limit blocks the command.

PROGRAMMING PROCEDURE

A) Setting the programmer
1
Before commencing make sure that the door
is closed, the LCD display is off and the LEDS
L4,L5,L7,L8 are all lit.
LED L6 is off (travel limit activated)
2
Keep the "PROG" button held down for more than
4 seconds: The letter
"D1" (this is the parameter defi nition mode).
3
After about 1 second the programming steps
starting from step
If this is the fi rst time the system has been
programmed (EEPROM memory empty) none of
4
the parameters will have been set, meaning that
the numbers will fl ash at each step; if programming
is being carried out on a system which has already
been programmed, fl ashing will depend on the
value read from EEPROM when switching on
(previously set parameters may therefore be
checked). Press the "PROG" button to change
the setting.
5
As you can see in fi gures 4-5, pressing the "PROG"
button when the display is not fl ashing will force
the number to fl ash.
This operation can be repeated as many times
as required until the desired setting has been
obtained.
6
Note: While "SEL" is pressed LED "L3" will remain lit
After the sixth stage, number "6" indicated, the
8
next time you press the "SEL" button moves
you to stage
between the confi guration of the system and the
deceleration sensor/work time programming.
There are now three possibilities:
- after about 20 seconds of inactivity (without pressing any
buttons) the programmer saves the set parameters and leaves
the programming mode.
- pressing the "SEL" button moves you back to step "1".
- pressing the "PROG" button moves you to the next stage.
DISPLAY
FIXED
1
TD: open-close (*)
2
Automatic reclosing enabled
3
Prefl ashing enabled
4
Travel limits enabled
5
Warning lights fl ash continuously
6
Deceleration enabled
* Travel direction inversion only active during the closing stage.
** For optimum operation of the device, avoid disabling the travel limits.
18
will appear on display
will appear on the display.
Pressing "SEL" moves you on
7
to the next programming stage.
It is not possible to return to the
previous programming stage so
carry on until the last stage and
the cyclical programming cycle
will return you to stage "1"
, which indicates the separation
FLASHING
TD: open-block-close-block
Automatic reclosing disabled
Prefl ashing disabled
Travel limits disabled (**)
Warning lights fl ash intermittently
Deceleration disabled