Switch on the power and make sure that the indicator LEDS are in the following
condition
- L1 Power on LED
- L2 Wrong battery connection LED
- L3 Battery charging LED
- L4 Manual operation indicator LED
- L5 Transmitter code programming indicator LED
- L6 Safety LED for the blocking button "TB"
- L7 Safety LED for the stop photoelectric cells "FTC_S"
- L8 Safety LED for the inverting photoelectric cells "FTC_I"
Note
: If this LED is "on" invert the battery power cables immediately.
(3)
Note
: This LED is "on" when the battery is charged.
(4)
Note
: Check that the activation of the safety devices switches the corre-
(5)
sponding LEDS off.
If the green power on LED doesn't light up check the condition of the fuses
and the power cable connection at the transformer primary.
If one or more of the safety LEDS do not light up check the contacts of the
relative security devices and check that the unused safety device contacts have
been bridged.
INDICATIONS ON THE DISPLAY (D1)
Alarm indications
System not programmed
You have to enter the programming mode to program the system
Out of position
When carrying out an installation you will have to enter programming in order to
program the gate travel distances. During normal operation it indicates that the
"automatic repositioning" procedure is about to take place (see page 17). In
this case any commands received (TA, TC or TD via radio) will automatically
start this procedure.
Caution! The gate moves automatically without waiting for a com-
mand.
Block during encoder programming
ThishappenswhenanN.C.contactisactivated(TB,FTC_I,FTC_S)duringencoder
programming or automatic repositioning. Once the passive state of the security
devices has been reset the gate/door will start moving again automatically.
Safety test error
Check the condition of the safety devices and make sure that the alarm cuts in
when an obstacle interferes with the beam (the relative LED will switch off). In
case of anomalies replace the damaged safety device or bridge the contact and
disactivate the safety test (parameters 7 and/or 8).
Attention! When programming the system parameters the letter "A" flashing indi-
cates that the FTC_S input is being used to connect a stop photoelectric cell.
Motor feed error
This occurs when the programmer sends a command to the motor and nothing
happens (the motor doesn't move). Check the motor faston connections and the
condition of the fuses "F1" and "F3" and then give another opening or closing
command. If the motor still doesn't move you are faced with either a mechanical
problem or an ECU problem.
A command was received with the motor released
on
Block the motor (see "MANUAL RELEASE" on page 14) and give another com-
off
(3)
mand.
off
(4)
off
off
Encoder count error
on
(5)
on
(5)
An encoder signal problem has occurred; check all relative connections and either
on
(5)
reprogram the system or carry out the automatic repositioning procedure (see
page 17). If the problem continues replace the encoder card.
Encoder direction error
The gate/door movement direction is different from encoder (e.g.: the gate closes
while the programmer is carrying out an opening cycle). Check the motor feed
connections.
Block caused by a flat battery
The programmer is blocked because the battery is flat during a blackout. In this
situation all received commands will be ignored.
Current sensor error
With a stopped motor this symbol indicates that there is a problem with the
current sensor
Motor error
This symbol indicates that there is a problem with the motor relays
Operational indications
Opening stage
Block
Pause for automatic reclosing (if activated)
Closing stage
Current sensor updating (only during programming)
Battery mode with a fully charged battery
Battery mode with a non fully charged battery
15