Installation

Installation information
The following information given here is not an instruction, but simply meant to
give the user a better understanding of the installation.

Condition of installation

Installation place
The pool heat pump must be installed outside with more than 2 to 3,5m
distance of the Pool basin according to laws' in force (NF C 15 100).
Install pool heat pump on a flat, horizontal, and stable surface. (Concrete
base would be ideal).
Maintain 1 m space in back (evaporator air inlet) and 3 m on the outlet side
of the fan.
Outlet air flow:
Provide space to allow access to temperature controller.
Make sure that the discharged air will not be sucked into the evaporator
again.
To perfect your installation
Avoid directing the flow of ventilated air towards a sensitive noise zone (room
window for example), or a space where persons normally stay (the discharged air
will be cold)
Avoid positioning pool heat pump on a surface that can transmit vibrations.
3m
26
Inlet air flow:
1m
Water inlet
Water outlet